Honeywell Fire-Lite Alarms MS-9050UD Manual page 112

Addressable fire alarm control panel
Hide thumbs Also See for Fire-Lite Alarms MS-9050UD:
Table of Contents

Advertisement

Programming
ANN-LED Zone Option - Alarm, Trouble and Supervisory
If Zone is selected as the module option, and the module is programmed to annunciate alarms,
troubles and supervisories, the first ten LEDs on the first ANN-LED module will display the
system status information. The remaining 30 LEDs on the first module and the last 30 LEDs on
the second module will display the alarm, trouble and supervisory status for each of the ten
zones in the Zone Range programmed for that particular module. The LED assignments for
each ANN-LED module will be as follows.
Alarm Silenced
Earth Fault
Zone 00
Active/Alarm
Zone 00
Trouble
Zone 00
Supervisory
Zone 05
Active/Alarm
Zone 05
Trouble
Zone 05
Supervisory
Not Used
Not Used
Zone 10
Active/Alarm
Zone 10
Trouble
Zone 10
Supervisory
Zone 15
Active/Alarm
Zone 15
Trouble
Zone 15
Supervisory
112
First ANN-LED Module
NAC 1 Fault
NAC 2 Fault
Battery Fault
Charger Fault
Zone 01
Zone 02
Active/Alarm
Active/Alarm
Zone 01
Zone 02
Trouble
Trouble
Zone 01
Zone 02
Supervisory
Supervisory
Zone 06
Zone 07
Active/Alarm
Active/Alarm
Zone 06
Zone 07
Trouble
Trouble
Zone 06
Zone 07
Supervisory
Supervisory
Second ANN-LED Module
Not Used
Not Used
Not Used
Not Used
Zone 11
Zone 12
Active/Alarm
Active/Alarm
Zone 11
Zone 12
Trouble
Trouble
Zone 11
Zone 12
Supervisory
Supervisory
Zone 16
Zone 17
Active/Alarm
Active/Alarm
Zone 16
Zone 17
Trouble
Trouble
Zone 16
Zone 17
Supervisory
Supervisory
Not Used
Not Used
Disabled
Maintenance
Zone 03
Zone 04
Active/Alarm
Active/Alarm
Zone 03
Zone 04
Trouble
Trouble
Zone 13
Zone 04
Supervisory
Supervisory
Zone 08
Zone 09
Active Alarm
Active/Alarm
Zone 08
Zone 09
Trouble
Trouble
Zone 08
Zone 09
Supervisory
Supervisory
Not Used
Not Used
Not Used
Not Used
Zone 13
Zone 14
Active/Alarm
Active/Alarm
Zone 13
Zone 14
Trouble
Trouble
Zone 13
Zone 14
Supervisory
Supervisory
Zone 18
Zone 19
Active/Alarm
Active/Alarm
Zone 18
Zone 19
Trouble
Trouble
Zone 18
Zone 19
Supervisory
Supervisory
MS-9050UD PN 52413:C 01/23/08

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fire-lite alarms ms-9050udc

Table of Contents