Connect Control Box - 230 V, 50 Hz; Water Test Whirlpool & Electronics; Complete Finish Wall - Kohler Maestro K-842-V-AB Installation Instructions Manual

Whirlpool baths
Table of Contents

Advertisement

D. CONNECT CONTROL BOX - 230 V, 50 HZ
Connect service to the field wiring compartment of the
control box. The 50 Hz model control box contains blue
and brown wires and earth lug.
A 230 V, 15 A, 50 Hz dedicated circuit is required.
Provide an Earth Leakage Circuit Breaker.
Provide a separate equipment earthing conductor for the
inside earth lug. The earthing conductor must not be
connected to any current carrying conductor. Follow
local electrical codes. A 230 V, 15A, 50 Hz separate
circuit is required.
10. WATER TEST WHIRLPOOL & ELECTRONICS
Check all electrical connections. Make sure both
connections to the pump are securely tightened.
Fill bath to a level at least 2" above the top of the highest
jet.

11. COMPLETE FINISH WALL

CAUTION: Risk of product damage. Do not
support the weight of the whirlpool by the rim.
Protect whirlpool surface. Make sure the vinyl bead is
attached securely to the sides being built into the wall.
Cover framing and walls with gypsum wallboard.
Tape and mud drywall...seal drywall and joints under
bath rim. Install finished wall material to subwall. Seal
joints between the whirlpool rim and finished wall using
silicone sealant.
CA
111835-
(1093)
Blue
Neutral
(Neutral)
Brown
(Phase)
Wire Connectors
Operate whirlpool for 5 minutes and check all whirlpool
harness (piping) connections for leaks.
For additional information on whirlpool operation, see
Whirlpool Start-Up Instructions on page 14.
Bath Rim
12
Earth
(Ground) Lug
Earth
(Ground)
Phase (Line)
Earthing Lug (for
bonding in accor-
dance with national
and local codes)
Gypsum Wallboard Subwall
Finished Wall Material
Water-Resistant Sealant
2 x 4 Studding
Vinyl Tiling-In Bead
Kohler Co., Kohler WI

Advertisement

Table of Contents
loading

Table of Contents