I
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed.
This only indicates that the CPU configuration has been altered. There is
no technical problem.
Proceed as follows:
Ê Restart your server.
Ê As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
If a password is assigned, enter the password and press [Enter].
Ê Select the Save & Exit menu.
Ê Select Save Changes and Exit or Save Changes and Reset.
Ê Verify that the Global Error indicator stops flashing.
"Resuming BitLocker functionality" on page 112
Ê
11.3

Replacing a CPU or heat sink

Field Replaceable Unit
(FRU)
Tools: Phillips PH2 / (+) No. 2 screw driver
V
CAUTION!
CPUs are modules which are extremely sensitive to electrostatic
discharges and therefore must always be handled with care. After a CPU
has been removed from its protective sleeve or from its socket, place it
with its smooth side down on a non-conducting, antistatic surface. Never
push a CPU over a surface.