Replacing A Cpu Or Heat Sink - Fujitsu PRIMERGY RX4770 M6 Upgrade And Maintenance Manual

Table of Contents

Advertisement

"Switching on the server" on page
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the
message CPU has been changed.
This only indicates that the CPU configuration has been altered.
There is no technical problem.
Proceed as follows:
● Restart your server.
● As soon as the startup screen appears, press the [F2] function key
to enter the BIOS.
● If a password is assigned, enter the password and press [Enter].
● Select the Exit menu.
● Select Commit settings and Exit.
● Verify that the Global Error indicator stops flashing.
▶ If applicable,
"Installing the front cover with lock" on page
"Resuming BitLocker functionality" on page
11.4

Replacing a CPU or heat sink

For CPU1 or CPU2 on the bottom system board:
Field Replaceable Unit
(FRU)
Tools:
– Phillips PH2 / (+) No. 2 screw driver (for cover 2)
– Torx 30 screw driver (for CPU heatsink)
For CPU 3 or CPU 4 on the top system board:
Upgrade and Repair Unit
(URU)
RX4770 M6
60.
Upgrade and Maintenance Manual
Processor (CPU)
61.
104.
Hardware: 20 minutes
Software: 5 minutes
Hardware: 10 minutes
Software: 5 minutes