5
Cell Control Board - 10000432

5.1 New Features

A new cell control board has been developed that is backwards compatible with the previous 10000092, 461E90, and
10000311 boards. New features include:
1.
Up to 1200VDC input operation
2.
630, 690, 750V jumpers for high bus voltage fault. Jumper is soldered in place.
3.
Resistor select for 400 or 450V electrolytic capacitors
4.
Cell precharge compatible. Jumper installed if not used.
5.
Out of Saturation latch handled in EPLD software, not in hardware.
6.
Suffix .7X series specific to MicroHarmony

5.2 Outline, Mounting, and Connections

CN6
CN8
CN7
8in
P/N, S/N, REV,
Date Code, etc
Connector
CN1
Temperature sensor
CN2
3-phase cell input voltage
CN3
2/3, 1/3 dc bus
CN4
+/- dc bus
19001467: Version 1.0
CN4
CN3
CN2
CN5
WARNING
High Voltage
CN10
12.9in
Function
2
7 (3 used, remainder removed)
4 (2 used, remainder removed)
4 (2 used, remainder removed)
s
Cell Control Board - 10000432
DC BUS
INDICATOR
CN1
CN9
Pins
5
Link ON
FAULT
Q1
Q2
Q3
Q4
Mating
Connector
089591
089399
089397
089397