MicroHarmony Cell Sizes 40 - 260A Manual
11.11.2 CCB to Modulator
The response data for Mode 11 data from the cell provides discrete indicators that show whether voltage is present at
the output terminal of each of the power cell switching devices. Also included is a Bypass Available status bit that the
Host can query to determine if the Cell Bypass option is available on the cell. (The Next Gen Control Software
doesn't test this bit because the bypass, when it exists, is always mechanical.)
Table 11-13: Mode 11 Data from Power Cell to Modulator
0
1
2
3
4
5
6
7
19001467: Version 1.0
Bit
1 -> Mode definition bit 0
1 -> Mode definition bit 1
Q1 Blocking Indicator (Blocking = 1)
Q2 Blocking Indicator (Blocking = 1)
Q3 Blocking Indicator (Blocking = 1)
Q4 Blocking Indicator (Blocking = 1)
Cell Bypass Option Available
Odd Parity Bit
∇ ∇ ∇
s
Communication Protocol
Description
11
11-9