C-10
17. Press the Enter key.
The following message will appear in the Status Display:
B C T Y P E = C O D E 3 9
P l e a s e W a i t
Up to 10 seconds is required for warming the lamps and
processing the data. Within 10 seconds, one of the following
messages will appear in the Status Display:
B C T Y P E = C O D E 3 9
(A)
<NOT FOUND>
This display indicates that the bar code was not read for one
of the following reasons:
• The type of bar code placed on the imaging guide is not the
type indicated in the Status Display; or
• The bar code is not positioned properly or faces in the
wrong direction on the imaging guide; or
• The bar code quality is poor.
The following action(s) should be taken:
• Verify the type of bar code placed on the imaging guide.
• Verify the position of the bar code placed on the imaging
guide.
• Clean the Imaging Guides if required.
NOTE: Press the Stop or End key to return to the Function
65 menu.
B C T Y P E = C O D E 3 9
(B)
<PARTIAL>
This display indicates that a start character was probably
recognized, but some of the remainder of the bar code was
unreadable.
The bar code was not read for one of the following reasons:
• The bar code is not positioned properly; or
• The bar code quality is poor.