Kodak 500 User Manual page 39

Kodak user's manual imagelink tm scanner 500
Hide thumbs Also See for 500:
Table of Contents

Advertisement

Error Code
E136
Bar Code
Hardware Error
E137
Footswitch
Not Machine Set
E138
Accessory
Off Via Fnc Code
E139
ConfirmTone
Not Mach Enabled
E150
Buffer Data
Transfer To Host
E151
Buffer Data
Transfer To Host
E152
Scanning
Try Again
E204
Re-Scan
Skew Monitor Err
E205
IA Overflow
Press Next Key
E207
Printer
Hardware Error
E208
Bar Code
Hardware Error
A-61408
September 1995
Description
Tried to use a Bar Code Reader
function code (60-65) after the
following two events occurred:
• The message E208 Bar Code
Hardware Error or E640-645
Bar Code Health Check Err was
displayed at power on, and
• The C key was used to clear
the message (but the error
status was not cleared.
Tried to use footswitch function
code but the footswitch accessory
is not enabled.
Tried to use an accessory that is
enabled for the current application
mode during mode configuration,
but the accessory is presently
disabled via a function code.
Tried to use a Confirmation Tone
function code (F53, F63, F75) but
Confirmation Tone is not enabled.
Tried to change function codes
via function code F02. This
function cannot be performed
because scanned images still
remain in the image buffer.
Tried to use the bar code test via
function code F65. This function
cannot be performed because
scanned images still remain in the
image buffer.
Tried to enter a function code
while scanning.
Tried to scan a document that is
skewed greater than the
maximum skew angle which has
been set for the current
application mode and less than 30
degrees.
One of the three image address
fields has been overflowed. For
example, if the level 1 field is set
to two digits, up to 99 level 1
documents may be scanned, the
100th document will cause an
overflow.
At power on, a hardware error has
been detected in the Document
Printer. The E236 Turn Off
Accessory message is also
displayed.
At power on, a hardware error has
been detected in the Bar Code
Reader. The E236 Turn Off
Accessory message is also
displayed.
Action
Press C to clear the error condition.
Press C to clear the error condition. If
the footswitch accessory is desired,
service must be called to change the
mode configuration.
After pressing C, press F and enter
the function code that enables the
desired accessory.
Press C to clear error condition. If
Confirmation Tone is required, contact
your system administrator.
After pressing C enter F02 again. If all
images have not been read by the
host, the error message will be
displayed again. If this cycle
continues, contact your system
administrator.
After pressing C enter F65 again. If all
images have not been read by the
host, the error message will be
displayed again. If this cycle
continues, contact your system
administrator.
Press the STOP/END key to stop
scanning.
Note the document that was skewed
and press C to clear the message.
After pressing C, press the Next key
or one of the three Level keys to
change the image address or image
level so the corresponding field does
not overflow.
Press C to clear the error condition
and contact System Administrator to
disable printer.
Press C to clear the error condition
and contact System Administrator to
disable printer.
4-5