5.3 Tools and consumables

Tools for mounting the protective housing:
Drill machine and drill (Ø 10 mm)
Screws (Ø 6 to 8 mm) and suitable washers or assembly dowel (Ø 10 mm) for attaching the protective hou-
sing, in each case 4 items
Spanner of a suitable size for the fastening screws
Tools for electrical installation:
Flat head screwdriver, blade width 2.5 or 3.5
Phillips screwdriver, size PZ2
Crimp tool with square crimping, e.g.:
KNIPEX 975304 or PHOENIX Crimpfox UD 6-4 1205244
Shield connection set for twisted pair cable: PRUFTECHNIK item no.: VIB 6.725-100
Heat gun with reduction nozzle for shield connection set
Standard tool for electric installations (wire cutters, wire stripper)
Suitable spanner for the cable glands:
M12 > size 16; M20 > size 24; M32 > size 36
Materials for electrical installation:
3-wire electric cable for low voltage supply
Shielded industrial Ethernet cable (CAT 6 / CAT 7)
Isolated ferrule for connecting the following lines:
 Supply, e.g.:
KLAUKE 472/8 (1.5 mm² / black)
Sensor cable (VIB 90061, VIB 90008) and digital inputs/outputs e.g.:
KLAUKE 469/10 (0.5 mm² / white),
Shield via KLAUKE 472/12 (1.5 mm² / black)
Ethernet e.g.:
KLAUKE 167/HL (0,25 mm² / blue),
Shield via KLAUKE 472/12 (1.5 mm² / black)
Suitable strain relief for cable protection
Cable tie or Velcro fastener to fix the cable in place
Labels to mark the cable routes