Page 1
Detachable Jaw True-rms Clamp Meter Calibration Manual...
Page 2
Calibration Manual Safety Information A Warning identifies conditions and actions that pose hazard(s) to the user. A Caution identifies conditions and procedures that could cause Meter damage, equipment under test damage, or permanent loss of data. Symbols used on the Product and in this manual are explained in Table 1. XWWarning To prevent possible electrical shock, fire, or personal injury: •...
Page 3
When batteries are changed, ensure that the calibration seal in the battery compartment is not damaged. If damaged, the Product may not be safe for use. Return the Product to Fluke for replacement of the seal. • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a product, probe, or accessory.
Page 4
shuts down when the battery reaches 2.0 V. Do not dispose of this product as unsorted Conforms to relevant North municipal waste. Go to Fluke’s website for American Safety Standards. recycling information. IEC Measurement Category III CAT III equipment has protection against...
Detachable Jaw True-rms Clamp Meter The Meter The Meter Clamp Meter fig_01_365.eps Figure 1. The Meter Specifications Electrical Specifications AC Current Range ............. 200.0 A Resolution ..........0.1 A Accuracy ..........2 % ±5 digits (45 – 65 Hz) 2.5 % ±5 digits (65 – 400 Hz) Crest Factor ..........
Calibration Manual Accuracy ..........1 % ±5 digits Mechanical Specifications Size (L x W x H) ........225 x 65 x 46 mm Weight............. 275 g (including batteries) Jaw Opening ........... 18 mm Detachable Jaw Cable Length ....900 mm Environmental Specifications Operating Temperature......
Detachable Jaw True-rms Clamp Meter Performance Tests Performance Tests XWWarning To prevent possible electrical shock, fire, or personal injury, do not perform the performance test procedures unless the Product is fully assembled. The following performance tests verify the complete operation of the Product and check the accuracy of each function against the Product’s specifications.
The equipment listed in Table 3 is required for calibration adjustment. Table 3. Required Equipment Equipment Required Characteristics Recommended Model Calibrator 4.5 digit resolution Fluke 55xxA Calibrator Wired coil 20 turns Power Supply +3.0 V Common power supply or a 2 x AA battery container...
Page 9
Detachable Jaw True-rms Clamp Meter Calibration Adjustment 8. See Table 4 fand apply each required output from the Calibrator to the Product. 9. Wait for the reading to become stable. 10. Push to confirm and advance to each next step. 11.
Page 10
Calibration Manual Table 4. Adjustment Procedure (cont.) Test Product Action (Switch Reading Position) C012 Calibrator output 10A @ 50 HZ, allow the reading to stabilize, wait 4 seconds, Push AC Amps C013 Calibrator output 2.5A @ 50 HZ, allow the reading to stabilize, wait 4 seconds, Push ...
Detachable Jaw True-rms Clamp Meter Maintenance Maintenance Clean the Product WCaution To prevent possible damage to the Product or to equipment under test, do not use abrasive cleaners. They will damage the case. To clean the Product, use a cloth with a mild cleaning solution. Battery Replacement XW Warning To prevent possible explosion, fire, or personal injury, replace...
Figure 2. Changing the Batteries User Replaceable Parts User replaceable parts are listed in Table 5. Table 5. User Replaceable Parts Fluke Part Description Number BATTERY,PRIMARY,ZN- 376756 MNO2,1.5V,2.24AH,15A,LR6,ALKALINE,AA,14X50MM,BULK 3837209 FLUKE-365-2008,BATT DOOR 3858245 SOFT CASE,BLACK/YELLOW,FLUKE-365 3622684 MANUAL,USER MANUAL, FLUKE-365 855742 TL75-4201,TEST LEADS 3890706 LABEL,CALIBRATION SEAL,F362/365...
Page 14
Introduction Warning Read "Safety Information" before you use the Meter. The Fluke 365 is a true-rms hand-held, battery-operated clamp meter (the Meter) that features a detachable Jaw. The Meter measures: • ac and dc current • ac and dc voltage •...
Users Manual Safety Information A Warning identifies conditions and actions that pose hazard(s) to the user. A Caution identifies conditions and procedures that could cause Meter damage, equipment under test damage, or permanent loss of data. Symbols used on the Meter and in this manual are explained in Table 1.
Page 16
Detachable Jaw True-rms Clamp Meter Safety Information Warning To prevent possible electrical shock or personal injury, follow these guidelines: • Use the Meter only as specified in this manual or the protection provided by the Meter can be compromised. • Examine the case before you use the Meter.
Page 17
Users Manual • Have the Meter serviced only by qualified service personnel. • Be careful around voltages >30 V ac rms, 42 V ac peak, or 60 V dc. Such voltages pose a shock hazard. • Do not apply more than the rated voltage, as marked on the Meter, between the terminals or between any terminal and earth ground.
Page 18
The Meter shuts down when the Double insulated battery reaches 2.0 V. Do not dispose of this product as unsorted municipal waste. Go to Conforms to relevant North American Fluke’s website for recycling Safety Standards. information.
Page 19
Users Manual Symbol Meaning Symbol Meaning IEC Measurement Category III CAT III equipment has protection Application around and removal from against transients in equipment in CAT III HAZARDOUS LIVE conductors is fixed-equipment installations, such permitted. as distribution panels, feeders and short branch circuits, and lighting systems in large buildings.
Page 20
Detachable Jaw True-rms Clamp Meter The Meter The Meter Clamp Meter...
Page 26
Detachable Jaw True-rms Clamp Meter The Meter...
Page 27
Users Manual Specifications Electrical Specifications AC Current Range ............. 200.0 A Resolution ..........0.1 A Accuracy ..........2 % ±5 digits (45 – 65 Hz) 2.5 % ±5 digits (65 – 400 Hz) Crest Factor ..........2.5 @ 125 A 1.55 @ 200 A Add 2 % for C.F.
Page 28
Detachable Jaw True-rms Clamp Meter Specifications Resolution ..........0.1 V Accuracy ..........1.5 % ±5 digits (45 – 400 Hz) DC Voltage Range .............600.0 V Resolution ..........0.1 V Accuracy ..........1 % ±5 digits Resistance Range .............600.0 Ω/6000 Ω Resolution ..........0.1 Ω/1 Ω Accuracy ..........1 % ±5 digits Mechanical Specifications Size (L x W x H) ........225 x 65 x 46 mm...
Page 29
Users Manual Environmental Specifications Operating Temperature......-10 °C to +50 °C Storage Temp ......... -40 °C to +60 °C Operating Humidity ......... Non condensing (<10 °C) ≤90 % RH (at 10 °C to 30 °C) ≤75 % RH (at 30 °C to 40 °C) ≤45 % RH (at 40 °C to 50 °C) (Without Condensation) Operating Altitude ........
Page 30
Detachable Jaw True-rms Clamp Meter Specifications Safety Compliance........ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 UL 61010-1:2004 EN/IEC 61010-1:2001 to 600V CAT III Pollution Degree 2 Agency Approvals ........Batteries..........2 AA, NEDA 15A, IEC LR6 Learn more about measuring tools on our website.