Installation and Operation

7.2 Data line

For the connection to the data network, the system module provides two equivalent ports:
LAN connection terminal for Ethernet cable with pre-assembled RJ45 connector.
Terminals 8 to 12 for Ethernet cable with open end.
To connect an Ethernet cable with RJ45 connector, proceed as follows:
Open a sensor cable gland (M32).
l
Take the seal out of the cable gland.
l
Remove one of the outer sealing inserts (1).
l
CAUTION!
Risk of injury due to sharp knife blade!
A sharp knife blade can cause cuts if used improperly.
Always cut away from your body.
Use work gloves.
Cut the seal at the opening radially using a sharp knife (2).
l
Place the Ethernet cable across the incision to the opening (3).
l
1 : Remove the sealing
insert
Place a cable loop in order to not put any strain on the connection during subsequent service work.
l
Insert the cable end with the plug into the protective housing.
l
If necessary, pull the Ethernet cable to a length appropriate for the connection.
l
Insert the seal back into the cable gland.
l
Connect the Ethernet cable to the LAN terminal.
l
Use the spanner to close the cable gland.
l
32
2 : Cut the seal
Seal with 8 sealing inserts (ø 5.3 mm)
3 : Insert the cable
Edition: 03.2019