Installation and Operation
Shield connection
The PRÜFTECHNIK shield connector for sensor cables (VIB 6.726-100) allows you to prepare the sensor cable for
connection to the shield terminal in just a few simple steps.
The equipment supplied includes 100 solder sleeves. Per solder sleeve one single-core shield cable
(AWG22 /0.38 mm²) is additionally required.
CAUTION!
Risk of burns through direct contact!
Heating tool and assembly become hot during installation.
- Allow tool and the assembly to cool down before handling.
Risk of burns from hot air jet!
The hot air jet can cause burns on the skin or inflame clothing.
- Keep the heating tool away from your body during operation.
- Do not point the heating tool at persons.
- Use a suitable reducing nozzle to direct the air jet onto the solder joint.
Danger from harmful fumes!
If the cable assembly heats up too much, it may char or burn. Charring or burning the cable assembly will
produce fumes that may cause eye, skin, nose and throat irritation.
- Follow the installation instructions carefully.
- Avoid charring or burning the cable assembly.
- Use adequate ventilation.
Note
Hot air jet can damage the cable!
Improper use of the heating tool can cause the cable to heat up too much and damage it.
- Heat the cable assembly slowly and carefully.
36
Transparent sleeve with fluxed solder preform
Length: 42 mm [1.655"]
Diameter: 6 mm [0.235"]
Edition: 03.2019