POSITIONING UNDERGROUND
(CARRIED OUT ONLY BY AUTHORIZED RETAILER)
Turning to a STIGA retailer, the perimeter cable can also be installed using a specific wire-laying machine,
without using pegs.
4.5.2. JUNCTION OF THE PERIMETER CABLE.
CAUTION:
Danger of cutting hands.
Requirements and obligations:
• Joint for perimeter cable
• Electrician's scissors
• Pliers
GLOVES OBLIGATION:
Use protective gloves to avoid
cutting your hands.
During the installation of the cable or in case of accidental breakage, it may be necessary to make
junctions.
Procedure:
1. Disconnect the charging base from the power supply.
2. Place the perimeter cable as per position (A).
3. Insert the ends of the cable into the joint as per position (B).
4. Fully press the button on the upper side of the joint using a pair of pliers as per position (C).
5. The perimeter cable is properly installed on the joint (D).
BAN:
Do not use insulating tape or joints of any other type that do not guarantee
correct insulation (cable lugs, terminals, etc.). The soil moisture causes
oxidation and the interruption of the perimeter cable.
A
EN
B
CAUTION:
Danger of dust in the eyes.
• Gloves
• Glasses
GLASSES OBLIGATION:
Use safety glasses to avoid the
danger of dust in the eyes.
C
4. INSTALLATION
D
25