PCA Switch and Strap Settings

Note 1: Pin 1 is designated by a white dot on all of the PCAs. These
tables list the factory default settings.
Note 2: Some of the PCAs listed in this section are no longer being
manufactured. These PCAs are identified by an (MD) following the
PCA's Product Equipment Code.
Table 7

NT6M62xx CPU PCA

Switch #
S2
Jumpers
J3
Table 8

CPU LED display codes

LED
Alarm level
BLANK
N/A
U.
N/A
P.
N/A
H.
N/A
r.
N/A
L.
N/A
E.
N/A
d.
Critical Level 3
c.
Critical Level 2
b.
Critical Level 1
A.
Critical Level 0
9.
Major Level 3
8.
Major Level 2
Position
1 OFF
2 OFF
3 ON
4 OFF
Pin
1-2
Notes
Power failure
Busak faulty
Wait faulty
Processor failed - halt
Processor reset - initial start-up
Clock faulty (also indicated by lack of
decimal point)
Invalid CPU response (also displayed
whenever switch 3 on SW2 is in the OFF
position
Processor switch occurs
Processor switch occurs
Processor switch occurs
Alarm only, no processor switch
Processor switch occurs
Processor switch occurs