Miscellaneous PCA Replacement Procedure 33
Procedure 1
Miscellaneous PCA replacement
Step
16
Switch Processors to make the standby active. At the mainte-
nance terminal, enter:
>SWACT (cr)
The old standby is now the active processor.
WARNING
This should not be done at a high traffic period, it may cause
a loss of AMA.
17
Verify replacement PCA has corrected original error.
18
When all maintenance activities are complete, be sure to
replace the front panel of the BMC. Carefully line up the four
captive screws of the front panel with their mounting holes.
Tighten the captive screws; but do not bear down.
The procedure is complete.
Description
BMC II AMAT Quick Reference Guide