Interface Pca (Nt6M94Xx) Replacement - Nortel DMS-10 Series Quick Reference Manual

Automatic message accounting transmitter style billing media converter ii
Hide thumbs Also See for DMS-10 Series:
Table of Contents

Advertisement

Power Supply Replacement Procedure (NT6M71xx) 55
Procedure 9
Power Supply (NT6M71xx) replacement
Step
12
Apply power to standby chassis by operation of the +8 V dc red
rocker switch on the power supply.
Wait for start-up activity to end and the message, Software
Loaded or S/W Loaded to print. For Turbo BMCs and Non-
Turbo BMCs equipped with 1 GB disk drives, wait for the CP
S/W Loaded message to print.
13
Place the active processor unit in PRIME mode. At the Switch
and Status Panel of the BMC:
a. Depress the P side of the O/P Mode Select Switch.
b. Turn the Mode Switch to the right and release.
14
Make the disk system redundant. At the maintenance terminal,
enter:
>DISK MODE xx (cr)
where: xx - disk mode: AP - A PRIME (if mode is A only)
The BMC will begin a disk copy, this may take several hours,
depending on how much data is stored and the disk capacity.
Proper response:
(from disk mode AO)
DISK MODE: AP
or
(from disk mode BO)
DISK MODE: BP
15
To clear any alarms on the standby processor, enter at the main-
tenance terminal:
>DOS S RSERR 00 (cr)
Alarms will clear on the standby processor if there are no faults.
16
To clear any alarms on the active processor, enter at the mainte-
nance terminal:
>RSERR 00 (cr)
Alarms will clear if there are no faults.
17
When all maintenance activities are complete, be sure to
replace the front panel of the BMC, if removed. Carefully line
up the four captive screws of the front panel with their mount-
ing holes. Tighten the captive screws; but do not bear down.
The procedure is complete.