Guards And Related Components; Filters, Screens, And Sensitive Components; Table 1 Guards And Related Components; Table 2 Filters, Screens, And Sensitive Components - Milnor 30022X8R Maintenance Manual

Washer-extractor, topsuspended, oil bearings and grease seals
Hide thumbs Also See for 30022X8R:
Table of Contents

Advertisement

3.1.1.1

Guards and Related Components

Examine these items. If an item is damaged, missing, or has the wrong setting, correct this
discrepancy immediately to prevent injury.
Table 1.
Guards and Related Components
Mark
Do this each
1 2 3 4 5 6
x
day*
x
day*
x
200 hours
x
200 hours
x
day*
x
day*
3.1.1.2

Filters, Screens, and Sensitive Components

Remove contamination from these items to prevent damage and unsatisfactory
performance.
Table 2.
Filters, Screens, and Sensitive Components
Mark
Do this each
1 2 3 4 5 6
x
40 to 60 hours
x
600 hours
x 2400 hours
x
day*
x
200 hours
x 2400 hours
x 2400 hours
x
200 hours
Pellerin Milnor Corporation
BNUUUH01.R09 0000399322 A.6 A.26 A.9 11/4/21 11:27 AM Released
Component
guards, covers
safety placards
fasteners
anchor bolts and grout
door interlock
emergency stop button
(optional on some washer-
extractors)
BNUUUH01.R10 0000399352 A.6 A.26 A.19 11/16/21 10:29 AM Released
Component
inverter fans, vents, filters See
motors
entire machine
chemical inlet areas
strainer(s) for air inlet
water inlet strainers if sup-
plied by others
strainer in water regulator
for optional supply injec-
tor and pumped chemicals
on some models.
strainer for steam inlet.
(Steam is optional on
some models.)
More Data
Speak to your dealer or Milnor for replacement
components.
Fasteners must be tight.
Grout must be good. Bolts must be tight.
If the machine operates with the door open:
Immediately remove power.
Do not permit operation.
Speak to your dealer or Milnor.
See
Section 3.2.6 , page
30. Do a test of the control.
More Data. See also
Figure 9, page 25
. Keep good air flow.
Keep good air flow.
Remove excessive dust and dirt.
Some chemical supplies that stay on machine surfaces
will cause corrosion damage. See
25
and
Section 3.1.2 , page
page 9
for background information.
See
Figure 15, page 28
Remove strainers from incoming water lines and flush
with water.
See
Figure 11, page 26
See
Figure 14, page 28
Routine Maintenance
Section 3.1.2 , page 17
Section 3.2.3 , page
17. See also,
Section 2.2 ,
15