Guards And Related Components; Filters, Screens, And Sensitive Components; Table 1 Guards And Related Components; Table 2 Filters, Screens, And Sensitive Components - Milnor MWF100C7 Manual

Hide thumbs Also See for MWF100C7:
Table of Contents

Advertisement

Available languages

Available languages

Routine Maintenance
3.1.1.1

Guards and Related Components

Examine these items. If an item is damaged, missing, or has the wrong setting, correct this
discrepancy immediately to prevent injury.
Table 1.
Guards and Related Components
Mark
Do this each
1 2 3 4 5 6
x
day*
x
day*
x
200 hours
x
day*
x
200 hours
x
day*
x
600 hours
3.1.1.2

Filters, Screens, and Sensitive Components

Remove contamination from these items to prevent damage and unsatisfactory
performance.
Table 2.
Filters, Screens, and Sensitive Components
Mark
Do this each
1 2 3 4 5 6
x
40 to 60 hours
x
600 hours
x 2400 hours
x
day*
x
day*
x
200 hours
x
1200 hours
x
200 hours
x 2400 hours
x 2400 hours
16
BNUUUH01.R09 0000399322 A.4 A.26 A.9 11/4/21 11:27 AM Released
Component
guards, covers
safety placards
fasteners
safety stands, bars or pins
(painted red)
anchor bolts and grout
emergency stop button
(optional on some washer-
extractors)
mechanical brake
BNUUUH01.R10 0000399352 A.4 A.26 A.19 11/16/21 10:29 AM Released
Component
inverter fans, vents, filters See
motors
entire machine
chemical inlet areas
self-purging filter (and
regulator) for compressed
air
filter element for the filter
(and reguator)
mufflers, quick exhaust
valves
strainer(s) for air inlet
water inlet strainers if sup-
plied by others
strainer in water regulator
for optional supply
More Data
Speak to your dealer or Milnor for replacement
components.
Fasteners must be tight.
Speak to your dealer or Milnor for replacement compo-
nents. See the section "Use the Red Safety Supports for
Maintenance..." in the Safety chapter.
Grout must be good. Bolts must be tight.
See
Section 3.2.7 , page
32. Do a test of the control.
See
Section 3.3.3 , page
35. Do a test of the mechanical
brake. If it does not operate correctly, repairs are neces-
sary. Speak to your dealer or Milnor. This is not routine
maintenance.
More Data. See also
Figure 9, page 27
. Keep good air flow.
Keep good air flow.
Remove excessive dust and dirt.
Some chemical supplies that stay on machine surfaces
will cause corrosion damage. See
27
and
Section 3.1.2 , page
page 10
for background information.
See
Figure 15, page
30. Make sure the bowl drains
automatically.
Replace the filter if you cannot remove contamination.
See
Figure 16, page 31
See
Figure 14, page 30
Remove strainers from incoming water lines and flush
with water.
See
Figure 11, page 28
Section 3.1.2 , page 19
Section 3.2.3 , page
19. See also,
Section 2.2 ,
Pellerin Milnor Corporation