plumber the person(s) or contractor licensed or otherwise accepted by the local jurisdiction to
perform the plumbing work described herein, and qualified to do so.
electrician the person(s) or contractor licensed or otherwise accepted by the local jurisdiction
to perform the electrical work described herein, and qualified to do so.
chemical supplier the person(s) or contractor with detailed knowledge of 1) the machine con-
troller configuration and operation, and 2) the pumped chemical delivery system, if such a
system is to be used.

Notices

Qualified Personnel Only
you are a plumber, electrician, or chemical supplier, as defined above.

Machine Must Be Anchored

chine has been anchored. See BNWUUI03 "Handling a Washer-extractor from Delivery to Final
Location."
Other Tasks
— This document and the documents it references address common tasks that
the plumber, electrician, and chemical supplier will perform. Other tasks, not explained here, can
be needed. Information about these tasks is usually provided by the dealer, the Milnor
tions Engineering department, or the Milnor
facing with a remote Mildata

Utility Requirements and Related Information

Type of Information
equipment list showing
model and options
purchased
plumbing connection fitting
types, sizes, and locations
water pressure range
Cv value
steam pressure range
compressed air pressure
range
specified voltage
28
— Do not attempt to connect utilities to the machine unless
— Utility connections are to be made only after the ma-
®
Service department An example is electrical inter-
®
data collection system.
Value or Where to Find
For the dealer, see the order acknowledgement.
See the standard and options dimensional drawings for your mod-
el located at the back of the installation manual.
10 – 75 psi (69 – 531 kPa) required
See the specification sheet for your model available online at:
https://www.milnor.com/specification-sheets/. The Cv value as-
sists the piping designer in determining flow rates and pressures.
30 – 115 psi (207 – 793 kPa) required, if applicable
85 – 110 psi (586 – 758 kPa) required, if applicable
See the machine nameplate or the order acknowledgement.