1. Basic Operation

1.1 Removing the Battery

(1) Rotate the knob above the battery pack counter-clockwise.
(2) Lift up the battery pack and remove it from the instrument.

1.2 Attaching the Battery

(1) Place the channel on the bottom of the battery pack, onto the
protrusion of the instrument and push the battery pack down
into place.
(2) Turn the knob clockwise.

1.3 Turning the Power On and Off

To set power on :
To shut down
NOTE: The power is automatically turned off after 10 minutes
of inactivity (Factory default setting).
1.4 Centering and Leveling
(1) While watching the circular vial and the plate level, level the
instrument by using leveling screw and the tripod.
(2) You can confirm the instrument is leveled by using the laser
plummet
To activate laser
To

1.5 Target Sighting (Focusing)

1.5.1 Manual focus

Rotate the focus ring manually:
: