Cleaning The Flue Gas Fan - Viessmann Vitoligno 200-S Installation And Service Instructions Manual

High performance wood gasification boiler for split logs up to 50 cm long
Hide thumbs Also See for Vitoligno 200-S:
Table of Contents

Advertisement

Checking the doors for tightness
3.
2.
1.
Fig. 26
Observe the following sequence:

Cleaning the flue gas fan

Danger
Risk of burns from hot components.
Switch off the boiler and let it cool down.
Danger
Working on a running fan can cause serious
injury.
Turn off the boiler and safeguard against restart-
ing.
Commissioning, inspection, maintenance
(cont.)
B
A
4.
Undo nuts
.
A
Shift the hinge or lock plate. To do this with the lock
plate, adjust the nuts
Retighten nuts
.
A
Note
The flue gas fan requires cleaning in the following
cases:
Vibration noises occur due to impeller imbalance
(deposits on the impeller vanes).
Output is reduced.
B
on the eye screw.
39