Viessmann Vitoligno 200-S Installation And Service Instructions Manual page 55

High performance wood gasification boiler for split logs up to 50 cm long
Hide thumbs Also See for Vitoligno 200-S:
Table of Contents

Advertisement

Code 2
(cont.)
3.
/
for "Code 2".
|
~
4.
to confirm.
d
5.
/
for the required coding address.
|
~
6.
to confirm.
d
7.
/
for the required value.
|
~
8.
to confirm.
d
"Adopted" appears briefly on the dis-
play.
General
Coding
Coding in the delivered condition
Fault message output delay
80:6
Minimum fault duration of 30 s be-
fore a fault message is issued.
Automatic summer/wintertime changeover
81:1
Automatic summer/wintertime
changeover
Outside temperature time constant
90:128
Time constant for calculating the
adjusted outside temperature
21.5 h
Outside temperature offset
92:0
No outside temperature correction. 92:- 10
9.
Exit the service menu.
ä
Overview
The coding addresses are displayed in groups, subject
to system configuration:
"General"
See page 55
"Heating"
See page 56
"Boiler"
See page 57
"DHW"
See page 57
Possible change
Adjustable from 0 to 995 s. 1 step ≙
80:0
to
5 s.
80:199
81:0
Manual summer/wintertime change-
over
90:0
Fast (low values) or slow (high val-
to
ues) matching of the flow tempera-
90:199
ture, subject to the set value accord-
ing to changes in outside tempera-
ture; 1 step ≙ 10 min
Correction of the outside tempera-
to
ture by the value set in °C.
92:10
Codes
55