Figure 5.47
• It is possible to modify the value of parameter
12 from 01=10s to 120=1200s by pressing the
13 or 15 keys (each unit increase or decrease on
the display corresponds to 10 seconds).
• Press button 14 (Figure 5.43) to confirm the val-
ue entered. The display will show the following
(Figure 5.48) for 5 seconds, then move up to
the next level.
Figure 5.48
• Press the keys 13 and 15 simultaneously (Fig-
ure 5.43) to exit the level without changing the
value (return to the previous level).
To exit the parameters menu:
• wait 15 minutes without pressing any key;
• switch off the electric power supply;
• press the 13 and 15 keys simultaneously for 5
seconds (Figure 5.43) (return to previous level).

5.19 Selecting re-ignition frequency

When the boiler functions in normal on/off heat-
ing mode, the minimum time between two igni-
tions is set to 1 minute (re-ignition frequency).
This time can be changed from a minimum of
INSTALLATION
10 seconds to a maximum of 20 minutes in pro-
gramming mode, using either the control panel
or the remote.
• Enter "programming mode" by pressing the 13
and 15 keys simultaneously for 5 seconds (Fig-
ure 5.49) until HiS (Boiler History) appears on
the LCD display (Figure 5.50).
12
13
Figure 5.49
Figure 5.50
• Scroll through the various menus by pressing
the keys 13 (back) or 15 (forward), until PAr
(Parameters menu) appears on the LCD display
(Figure 5.51).
• Press the 14 key for 1 second to enter the se-
lected menu.
Figure 5.51
• Scroll through the various parameters by press-
ing the keys 13 (back) or 15 (forward), until P10,
which alternates with the parameter value, ap-
pears on the LCD display (Figure 5.52).
17
16
15
14
- 55 -