• Scroll through the various parameters us-
ing 13 or 14 until the LCD display shows
the code P03, indicating entry into "pa-
rameter P03" (Figure 5.48).
Figure 5.48
• Press 17 (Figure 5.46) to show the value
of parameter P03 on the LCD display (Fig-
ure 5.49).
Figure 5.49
• By using buttons 16 or 17 it is possible to
INSTALLATION
18
17
16
RESET
bar
RESET
bar
RESET
bar
modify the value of parameter 03 from 0
to 99 seconds.
• Press 13 or 14 (Figure 5.46) to confirm the
value entered and return to the list of pa-
rameters (Figure 5.48).
• Press the 18 button (Figure 5.46) to exit
"programming mode".
5.21 Selecting re-ignition frequency
When the boiler functions in normal on/off
heating mode, the minimum time between
two ignitions is set to 1 minute (re-ignition
frequency).
This time can be programmed from a min-
imum of 0 to a maximum of 255 minutes.
• Enter "programming mode" by holding
down buttons 18 and 19 for 5 seconds
at the same time (Figure 5.50). The code
P00 appears on the display, indicating en-
try into "parameter P00" (Figure 5.51).
19
13
14
Figure 5.50
Figure 5.51
• Scroll through the various parameters us-
ing 13 or 14 until the LCD display shows
the code P05, indicating entry into "pa-
18
17
16
RESET
bar
- 49 -