Selecting Re-Ignition Frequency - Biasi RINNOVA Series User Manual And Installation Instructions

Table of Contents

Advertisement

18
12
13
Figure 5.47
Figure 5.48
• Scroll through the various parameters us-
ing 12 or 13 until the LCD display shows
the code P03, indicating entry into "pa-
rameter P03" (Figure 5.49).
Figure 5.49
• Press 16 (Figure 5.47) to show the value
of parameter P03 on the LCD display (Fig-
ure 5.50).
Figure 5.50
• By using buttons 15 or 16 it is possible to
INSTALLATION
17
16
15
RESET
bar
RESET
bar
RESET
bar
modify the value of parameter 03 from 0
to 99 seconds.
• Press 12 or 13 (Figure 5.47) to confirm the
value entered and return to the list of pa-
rameters (Figure 5.49).
• Press the 17 button (Figure 5.47) to exit
"programming mode".

5.18 Selecting re-ignition frequency

When the boiler functions in normal on/off
heating mode, the minimum time between
two ignitions is set to 1 minute (re-ignition
frequency).
This time can be programmed from a min-
imum of 0 to a maximum of 255 minutes.
• Enter "programming mode" by holding
down buttons 17 and 18 for 5 seconds
at the same time (Figure 5.51). The code
P00 appears on the display, indicating en-
try into "parameter P00" (Figure 5.52).
18
12
13
Figure 5.51
Figure 5.52
• Scroll through the various parameters us-
ing 12 or 13 until the LCD display shows
the code P05, indicating entry into "pa-
17
16
15
RESET
bar
- 43 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rinnova m290e.24cmRinnova m290e.28cmRinnova m290e.32cm

Table of Contents