The user is responsible for periodically
checking the pressure of the heating sys-
tem.
If water needs to be added too often, have
the technical support centre check if there
are any leaks in the heating system or the
boiler itself.
Water leaks from the safety valve
Check if the filling cock is closed tightly (see
"Filling the heating circuit" on page 14).
Check on the pressure gauge that the heat-
ing circuit pressure is not close to 3 bar.
Should this be the case, drain a part of the
water from the system through the air relief
valves in the radiators in order to reduce the
pressure to a normal value.
In the case of malfunctions oth-
er than those described above,
shut down the boiler as de-
scribed in section "Shutdown"
on page 13 and call a techni-
cian from the authorised service
centre.
3.7 Displays in INFO mode
INFO mode is used to view boiler status in-
formation. In the case of a boiler malfunc-
tion, provide this information to the service
centre so that they can work out its causes.
To access INFO mode, press 19 (Figure
3.7) and hold for 5 seconds until the code
n02 shows on the display (Figure 3.8).
- 16 -
USEFUL TIPS
13
14
Figure 3.7
Figure 3.8
To scroll through the values, press 13 (in-
crease) and 14 (decrease). Press 18 and
hold for 5 seconds to exit INFO mode (Fig-
ure 3.7).
The table summarises the possible values
visible in INFO mode.
Table of
contents
n02
n03
n04
n05
n08
n09
n11
19
18
15
RESET
bar
Value shown
DHW output temp.
NTC return temperature (not
present)
Flue gas temperature (not
present)
Outdoor temperature
Maximum
set
fan
(RPM/100)
(not used)
Flow rate
17
16
speed