Figure 9.28
• By using buttons 16 or 17 (Figure 9.21) it
is possible to modify the value of parame-
ter A01 (Figure 9.29).
00 = Methane gas (G20)
01 = Propane gas - LPG (G31)
Figure 9.29
• Press 13 or 14 (Figure 9.21) to confirm the
value entered and return to the list of pa-
rameters (Figure 9.28).
• Press 13 and hold until the LCD display
shows the code A02, indicating entry into
"parameter A02" (Figure 9.30).
Figure 9.30
• By using buttons 16 or 17 (Figure 9.21) it
is possible to modify the value of param-
eter A02:
01 = high temperature (50/80°C)
02 = low temperature (28/55°C)
• Press 13 or 14 (Figure 9.21) to confirm the
value entered and return to the list of pa-
MAINTENANCE
RESET
bar
RESET
bar
RESET
bar
rameters (Figure 9.30).
• Press button 13 and hold until the LCD
display shows the code A21, indicating
entry into "parameter A21" (Figure 9.31).
Figure 9.31
• By using buttons 16 or 17 (Figure 9.21) it
is possible to modify the value of parame-
ter A21 (Figure 9.32).
00 = Room thermostat
01 = Remote control
Figure 9.32
• Press 13 or 14 (Figure 9.21) to confirm the
value entered and return to the list of pa-
rameters (Figure 9.31).
• Press the 18 button (Figure 9.21) to exit
"programming mode".