• Scroll through the various parameters us-
ing 13 or 14 until the LCD display shows
the message Cod, indicating entry into
"parameter Cod" (Figure 8.5), and then
displays three dashes "- - -".
Figure 8.5
• Press the 17 button to set "1 - -", then
press 13 to confirm the 1 and go to the
next segment.
• Press the 17 button to set "1 9 -", then
press 13 to confirm the 9 and go to the
next segment.
• Press the 17 button to set "1 9 8", then
press 13 to confirm the 8 and go back to
the list of parameters.
• The code A01 appears on the display, in-
- 60 -
GAS CONVERSION
18
17
16
RESET
bar
RESET
bar
dicating entry into "parameter A01" (Fig-
ure 8.6).
Figure 8.6
• By using buttons 16 or 17 (Figure 8.3) it is
possible to modify the value of parameter
A01 (Figure 8.7).
00 = Methane gas (G20)
01 = Propane gas - LPG (G31)
Figure 8.7
• Press 13 or 14 (Figure 8.3) to confirm the
value entered and return to the list of pa-
rameters (Figure 8.6).
• Press the 18 button (Figure 8.3) to exit
"programming mode".
• Calibrate the gas valve according to the
instructions in section "CHECKING THE
GAS SETTING" on page 55.
• Reposition the control panel and reas-
semble the front panel of the body.
• Apply the label indicating the type of gas
and the pressure value for which the unit
is set. The self-adhesive label is included
in the conversion kit.