Security Codes

The system supports up to 48 security codes, which can each be assigned one of 5 authority levels.
The authority level determines the functions each code can perform as follows:
Authority Levels
Level
User No.
Installer
01
System
02
Master
Partition
P1 = 03
Master
P2 = 25
(default)
P3 = 41
0-User
03-49
1-Arm Only see "user"
2-Guest
see "user"
3-Duress
see "user"
4-Partition
see "user"
Master
Refer to the user guide for detailed procedures on adding/deleting security codes and changing user
attributes.
The following is a brief description of how to add user codes.
Adding a User Code:
Deleting a User Code: Master code + [8] + 2-digit user no. + [#] [0]
Assigning Attributes: Master code + [8] + 2-digit user no. + [#] [attribute no.] + value
Arming Mode
NIGHT-STAY
(authority levels can be assigned to users 3-49 only; users 1 and 2 cannot be changed)
Functions
perform all security functions except can disarm only if used to arm;
can enter program mode; can change System Master code; cannot assign
any other user codes (default = 4112)
only one system master code per system; can perform all security
functions, add/delete users in all partitions, change system master code,
view event log, set system clock, program keypad macro, program
scheduled events, activate output devices (triggers/relays) (default = 1234)
Same as Master, except add/delete users limited to
assigned partition only, (these users can be assigned different authority
levels, if desired; any user can be assigned the partition master authority
level)
perform security functions (arm, disarm, etc.) only; cannot add/delete
users, view event log, set system clock or program scheduled events
arm system only
can disarm the system only if it was used to arm the system
performs security functions, but also silently sends a duress message to
the central station; reports as duress code user number.
See Partition Master paragraph above; used to assign
other user numbers as partition masters
Master code + [8] + 2-digit user no. + user's code
Attributes:
1 = Authority Level
2 = Access Group
3 = Active Partition(s)
for this user;
4 = RF Zone No.
5 = Open/Close Paging
6 = Open/Close Report to
Monitoring Station
SUMMARY OF ARMING MODES
Exit Delay
AWAY
Yes
STAY
Yes
Yes
INSTANT
Yes
MAXIMUM
Yes
Values
0-4 (see Authority Level table above)
0-8 (0 = not assigned to a group)
1, 2, 3
Enter partitions consecutively if more than
one and press [#] to end the entries.
Assigns user number to button type zone for
arm/disarm (keyfob must be enrolled in system
first; see Wireless Key Templates section)
1 for yes, 0 for no
1 for yes (default = yes for all users), 0 for no
Features for Each Arming Mode
Entry Delay
Perimeter Armed
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
Interior Armed
Yes
No
only those zones
listed in Night-Stay
zone list
No
Yes
6-5