The 4110XM is a microprocessor-based security control intended for hard-wired applications.

Zones Supported

Up to six (6) hardwire zones, having the following characteristics:
EOLR supervision supporting N.O. or N.C. sensors.
300-500 msec normal response.
Zone 3 programmable for Fast Response to open (10mS).

Security Codes

1 master code for entire system (user 1)
6 secondary user codes (users 2-7)
Duress code assigned as user 8

Keypad Panic Keys

Provides programmable panic key functions
Activated by wired keypads

Alarm Output

Provides a 12VDC, 2A output (assumes a fully charged 4AH battery is connected)
Steady output for Burglary/Panic, or pulsing output for Fire
Output is current limited
Communication Formats
ADEMCO Low Speed (Standard or Expanded): 1400Hz ACK/KISSOFF.
Sescoa/Radionics (Standard or Expanded): 2300Hz ACK/KISSOFF.
Ademco Express: DTMF, 1400/2300Hz ACK, 1400Hz KISSOFF.
ADEMCO Contact ID® ® ® ® : DTMF 1400/2300Hz ACK, 1400Hz KISSOFF.

Compatible Devices

Remote Keypads (up to 4)
Model
6150
Addressable keypads must be used in the non-addressable mode (Device Address 31), which is pre-set at
the factory. Do not set these keypads to any other addresses.
Optional Keyswitch
Model
4116
Type
Fixed English Keypad
Type
Keyswitch