Type 24
Silent Burglary
Type 77
Keyswitch
Type 81
AAV Monitor Zone
Type 82
Blockschloss
Types 90-93
Configurable
NOTE: All of the zone types described are available for the wireless portion of the system, if used.
• Usually assigned to all sensors or contacts on windows and infrequently used
exterior doors where siren sounding is NOT desired for alarms.
• Provides an instant alarm, with NO audible indication at any keypad or external
sounder, if the zone is faulted when the system is armed in the Away, Stay,
Instant, or Maximum modes.
• A report is sent to the central station.
• Assign to zone wired to a keyswitch.
• Do not use devices assigned as input type "BR" with this zone type.
• Assign to zone connected to AAV module.
• Monitors 2-way voice sessions as follows:
- When the zone is faulted, all alarm sounding and dialer reporting stops, except
for fire alarms, which immediately terminate the voice session and cause
a fire report to be sent.
- When the zone is restored (session ended), sounding resumes (if bell timeout
has not expired) and reports that were stopped are sent.
• Used with special blockschloss lock and key.
• System arms 5 seconds after the key is fully turned (arms MAXIMUM); key can
then be removed.
• When armed, the blockschloss zone is shorted. An open circuit on this zone causes
trouble condition.
• If zones are "not ready," the key will not turn fully and the system will not arm.
• Contact ID report code is 409.
• Once the system is armed using blockschloss, it can be disarmed only by the key;
wired keypads, RF keypads, and keyfobs cannot be used for disarming.
• If any zone in the system is assigned as blockschloss zone type, the system will not
arm in AWAY mode. The system can, however, be armed in STAY or INSTANT
modes from keypads and keyfobs even if the blockschloss zone is faulted.
• Allows for various custom responses.
• Options include response to entry/exit delays, response to opens/shorts, types of
alarm/trouble sounding, dial delay, and unique Contact ID report codes.
• Use *83 Menu mode to program these configurable zone types.
UL installations: Zone Types 90 -93 may not be used as fire or burglar alarm zones
on fire or UL burglar alarm installations.
3-5