Compatible 5800 Series Transmitters Table
Model
Product
5801
Wireless Panic
Transmitter
5802
Pendant
(Personal
Emergency Transmitter)
5802CP
Belt Clip (Personal
Emergency)
5802MN
Miniature (Personal
5802MN2
Emergency Trans.)
5804
Wireless Key
Transmitter
5804BD
Bi-Directional
Wireless Key
5806
Wireless
5807
Photoelectric Smoke
5808LST
Detectors
5809
Heat Detector
5816
Door/Window
5816MN
Transmitters
5816TEMP
Low-Temp. Sensor
5817
Multi-Point Universal
Transmitter
5818
Recessed Transmitter
5819
Shock Processor
Transmitter
5819WHS
Shock Processor
5819BRS
Transmitter
5827
Wireless Keypad
5827BD
Wireless Two-Way
Keypad
5849
Glassbreak Detector
5852
5890
PR Detector
5890PI
5899
Magnets
Input Type
Description
• Four pushbuttons, each with a unique input (loop) code.
UR or RF
• Programmable responses (e.g., Panic, Arm, Disarm, etc.)
• Has single pushbutton.
BR Only
• Usually programmed for response type of 24-Hr audible or 24-Hr Silent
(other zone responses are possible).
Same as 5802.
BR Only
Same as 5802.
UR or RF
• Has four pushbuttons, each with a unique input (loop) code.
BR Only
• Programmable responses (e.g., Arm, Disarm, etc.)
• House ID must be set.
BR Only
• Requires 5800TM Transmitter Module or 5883 Transceiver.
• Can indicate system status via its 2 LEDs and built-in sounder.
• Has four pushbuttons, each with a unique input (loop) code.
• Operates the system similarly to wired keypads.
One-piece smoke detectors with a built-in transmitter.
RF
One-piece rate-of-rise heat detector with a built-in transmitter.
RF
Has two unique input (loop) codes: one for a wired closed circuit contact
RF
loop; the other for its built-in reed switch (used with a magnet).
Transmits a fault condition when temperature drops below 45°F.
RF
Has three unique input (loop) codes: one for a "Primary" contact loop with
RF
programmable options; the others for two "auxiliary" closed circuit contact
loops.
• Reed switch magnetic contact sensor; easily hidden in the frame and
RF
edge of a door or window.
• Has a single unique input (loop) code.
• Connects to externally mounted inertia-type shock detector (not supplied).
RF
• Has built-in tampered cover switch.
• Has 3 unique input (loop) codes:
Loop 1: Terminals for a wired, N.C. sensor loop.
Loop 2: For a closed circuit contact loop using the built-in reed switch in
Loop 3: Terminals for a wired, closed circuit contact loop.
• Has built-in shock sensor.
RF
• Has built-in tampered cover switch.
• Has 3 unique input (loop) codes:
Loop 1: Built-in shock sensor loop wired to TB1 (normally closed).
Loop 2: For a closed circuit contact loop using the built-in reed switch in
Loop 3: Externally wired, closed circuit loop connected to TB2.
• Can be used to turn the burglary protection on and off.
Uses House
• Features the same built-in panic functions as wired keypads.
ID only
• The keypad is identified as zone "00" on wired keypads when it transmits
with a low battery.
• Requires 5800TM Transmitter Module.
Uses House
• Operates the system similarly to wired keypads, including panics.
ID only
• Can indicate system status via its 3 LEDs and sounder.
• Includes 3 panic keys.
• House ID must also be set.
RF
• 5849 requires both sound and shock of breaking glass to cause alarm to
be transmitted.
• 5852 uses intelligent acoustic processing.
Dual-element passive infrared detector/transmitter with built-in selectable
RF or RM
pulse count.
Note: There is a 3-minute lockout between fault transmissions to conserve
battery life.
Package of 4 magnets for use with 5816, 5817, and 5819WHS transmitters.
conjunction with a magnet.
conjunction with a magnet.
8-3