Honeywell ADEMCO VISTA-40 User Manual
Honeywell ADEMCO VISTA-40 User Manual

Honeywell ADEMCO VISTA-40 User Manual

2-partiotioned security system
Hide thumbs Also See for ADEMCO VISTA-40:
Table of Contents

Advertisement

3DUWLWLRQHG 6HFXULW\ 6\VWHP
8VHU *XLGH
N7003V3 5/04 Rev A

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell ADEMCO VISTA-40

  • Page 1 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A...
  • Page 2 – 2 –...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS SYSTEM OVERVIEW ........5 BYPASSING PROTECTION ZONES ..24 General ............5 Using the 6 BYPASS Key ....24 A Partitioned System ........5 Quick Bypass ..........25 Zones ............5 Displaying Bypassed Zones .....25 Fire Protection ..........6 ARMING PERIMETER ONLY ......26 Burglary Protection ........6 Alarms............6 Using the 3 STAY key......26 Memory of Alarm ........7...
  • Page 4 MAINTAINING YOUR SYSTEM ....46 Using the 5 TEST Key ......39 Taking Care of Your System ....46 Testing Your System ........39 Replacing Batteries in Wireless FIRE ALARM SYSTEM........40 Sensors ............46 In Case Of Fire Alarm.......40 Silencing Low Battery Warning Tones Silencing A Fire Alarm ......40 at the Keypad ...........47 Typical Trouble Displays ......41 Routine Care ..........47...
  • Page 5: System Overview

    System Overview General Your Honeywell security system consists of a main control panel, at least one keypad, and various sensors strategically positioned throughout the premises. The system offers you three forms of protection: burglary, fire and emergency. The keypad provides full control of system operation.
  • Page 6: Fire Protection

    System Overview (cont’d) Fire Protection The fire protection portion of your security system (if used) is always on and will sound an alarm if a fire condition is detected. Refer to the FIRE ALARM SYSTEM section for important information concerning fire protection, smoke detectors and planning emergency exit routes from your house.
  • Page 7: Memory Of Alarm

    System Overview (cont’d) Memory of Alarm When an alarm condition occurs, the keypad displays the number(s) of the zone(s) that caused the problem, and displays the type of alarm (ex. FIRE, ALARM). It remains displayed until it is cleared by disarming the system (see DISARMING THE SYSTEM section).
  • Page 8: Phone Access & Voice Response Capability

    System Overview (cont’d) Phone Access & Voice Response Capability Your system may include a 4285 or 4286 VIP module that will permit you to access the system via a Touch-tone phone, either on-premises or by call-in when away. The phone access feature will enable you to do the following: •...
  • Page 9: About The Keypads

    About The Keypads General IMPORTANT: If the keypad beeps rapidly upon entering the premises, it indicates that an alarm has occurred during your absence. LEAVE IMMEDIATELY and CONTACT THE POLICE from a safe location nearby. Your keypads allow you to control all system functions. The keypads feature a telephone style (digital) keypad and a Liquid Crystal Display (LCD) that shows the nature and location of all occurrences.
  • Page 10: Functions Of The Keypad

    Functions Of The Keypad DISPLAY SPEAKER ARMED AWAY STAY LEDS READY TEST BYPASS CODE CHIME INSTANT READY FUNCTION KEYS IMPORTANT!: When using the keypad to enter codes and commands, sequential key depressions must be made within 3 seconds of one another.
  • Page 11 Functions Of The Keypad (cont’d) ALPHA DISPLAY WINDOW: A 2-line, 4 MAXIMUM : Arms in manner similar 32-character Liquid Crystal Display (LCD). to AWAY mode, but eliminates the entry Displays protection point identification and delay period, thus providing maximum system status, messages, user...
  • Page 12 Functions Of The Keypad (cont’d) KEYS 0-9: Used to enter your individual 9 CHIME : Turns on & off the CHIME security access code(s). mode. When on, any entry through a LED READY INDICATOR: (GREEN) Lit protected delay or perimeter zone while the indicates system is ready to be armed, system is disarmed will cause a tone to while unlit indicates system not ready.
  • Page 13: Entry/Exit Delays

    Entry/Exit Delays General Information Your system has installer-programmed time delays, known as exit delay and entry delay. Whenever you arm your system, exit delay gives you time to leave through the designated exit door without setting off an alarm. Exit delay begins immediately after entering any arming command, and applies to all modes of arming protection.
  • Page 14: Security Codes & Authority Levels

    Security Codes & Authority Levels General Information At the time of installation, you were assigned an authority level and a personal four-digit security code, known only to you and yours. The security code must be entered when arming and disarming the system. The authority level defines the system functions that you can perform.
  • Page 15: Authority Levels

    Security Codes & Authority Levels (cont’d) Authority Levels Authority levels define the system functions a particular user can perform. Depending on the authority assigned to you, there are certain system functions you may be prohibited from performing. In summary, there are six authority levels, each having certain system restrictions as shown below.
  • Page 16: General Rules On Authority Levels And Changes

    Security Codes & Authority Levels (cont’d) General Rules on Authority Levels and Changes • A user may not delete or change the user code of the SAME or HIGHER authority than which he is assigned. • A user may only ADD users to a LOWER authority level. •...
  • Page 17: To Add A User

    Security Codes & Authority Levels (cont’d) To Add a User IMPORTANT: Temporary users should not be shown how to use any system function they do not need to know (e.g. bypassing protection zones). CODE 1. Enter Master or Manager code and press the key.
  • Page 18: To Change A User's Code

    Security Codes & Authority Levels (cont’d) The keypad now prompts for the user’s access to the PART.2 - SHOP? next partition (see GOTO command). Again press 0 0 = NO , 1 = YES or 1. If yes, the system will automatically assign a user number for use in that partition and will prompt for authority level and global arm options for this user within the partition (see previous...
  • Page 19: To Delete A User

    Security Codes & Authority Levels (cont’d) To Delete a User CODE 1. Enter Master or Manager code and press the key + user number to be deleted. 2. Enter Master or Manager code first entered. The system will recognize that the User number OK TO DELETE is already in use and will prompt to confirm that 0 = NO , 1 = YES...
  • Page 20: Accessing Other Partitions

    Accessing Other Partitions To Access Another Partition Each keypad is assigned a default partition for display purposes, and will show only that partition’s information. But, if the user is authorized, a keypad in one partition can be used to perform system functions in the other partition, by using the GOTO command.
  • Page 21 Accessing Other Partitions (cont’d) The prompt displays all the partitions. The user ARM P 1 2 3 4 5 6 7 8 may only arm/disarm the partitions they are HIT 0-8 X X X - - X - - assigned access to. To select the partition(s) that are to be armed, enter the desired number 1-8.
  • Page 22: Checking For Open Zones

    Checking For Open Zones Using the ✳ READY Key Before arming your system, all protected doors, windows and other protection zones must be closed or bypassed (see BYPASSING section). Otherwise the keypad will display a "Not Ready" message. Using the READY key will display all zones that are faulted, making it easier for you to secure any open zones.
  • Page 23: Displaying All Zone Descriptors

    Displaying All Zone Descriptors Using the ✳ READY Key The Alpha Keypads can also display all the zone descriptors that are programmed in your system. The abbreviated instructions for the READY key will appear first, followed by the zone descriptors. Displaying all descriptors is useful when you need to know the zone number of a particular zone, as when bypassing zones.
  • Page 24: Bypassing Protection Zones

    Bypassing Protection Zones Using the 6 BYPASS Key This key is used when you want to arm your system with one or more zones intentionally unprotected. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed. All bypasses are removed when an OFF sequence (security code plus OFF) is performed.
  • Page 25: Quick Bypass

    Bypassing Protection Zones (cont’d) Quick Bypass Your system allows you to easily bypass all open (faulted) zones without having to enter zone numbers individually. Note: All bypasses are removed when an OFF sequence (security code plus OFF) is performed. To use the Quick Bypass feature: BYPASS 1.
  • Page 26: Arming Perimeter Only

    Arming Perimeter Only (With Entry Delay ON) Using the 3 STAY key Use this key when you are staying home, but might expect someone to use the entrance door later. When armed in STAY mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises.
  • Page 27: Arming Perimeter Only

    Arming Perimeter Only (With Entry Delay OFF) Using the 7 INSTANT Key Use this key when you are staying home and do not expect anyone to use the entrance door. When armed in INSTANT mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises.
  • Page 28: Arming All Protection

    Arming All Protection (With Entry Delay ON) Using the 2 AWAY Key Use this key when no one will be staying on the premises. When armed in AWAY mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises. You may leave through the entrance door during the exit delay period without causing an alarm.
  • Page 29: Arming All Protection

    Arming All Protection (With Entry Delay OFF) Using the 4 MAXIMUM Key Use this key when the premises will be vacant for extended periods of time such as vacations, etc., or when no one will be moving through protected interior areas. When armed in MAXIMUM mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises.
  • Page 30: Disarming And Silencing Alarms

    Disarming And Silencing Alarms Using the 1 OFF Key The OFF key is used to disarm the system and to silence alarm and trouble sounds. See "SUMMARY OF AUDIBLE NOTIFICATION" section for information which will help you to distinguish between FIRE and BURGLARY alarm sounds.
  • Page 31: Using The Keyswitch

    Using The Keyswitch General Your system may be equipped with a keyswitch for use when arming and disarming a partition. A red and green light on the keyswitch plate indicate the status of your system as follows: Green Light: Lights when the system is disarmed and ready to be armed (no open zones).
  • Page 32: Chime Mode

    Chime Mode Using the 9 Key Your system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME mode. When activated, three tones will sound at the Keypad whenever a protected perimeter door or window is opened, and the Not Ready message will be displayed.
  • Page 33: Viewing Alarm Company Messages

    Viewing Alarm Company Messages General Information Users of the system may periodically receive messages on their display screens from their monitoring agency or installer. When a message is waiting to be viewed, the message shown below will appear. MESSAGE. PRESS 0 FOR 5 SECS.
  • Page 34: Panic Keys

    Panic Keys (For Manually Activating Silent And/Or Audible Alarms) Using Panic Keys Your system may have been programmed to use special key combinations to manually activate panic functions. The functions that might be programmed are Silent Emergency, Audible Emergency, Personal Emergency, and Fire. See your installer for the function(s) that may have been programmed for your system.
  • Page 35: Access Door Control

    Access Door Control General Information Your system may be set up such that a locked access door (such as in a lobby) can be unlocked momentarily or for a specific period of time, using a keypad command. Ask your installer if this has been done in our system. Executing To execute the access control function at the keypad, enter the following command:...
  • Page 36: Using #70 Relay Menu Mode

    Using #70 Relay Menu Mode General Information Your system may be set up so that certain lights or other devices can be turned on or off by using the #70 command from either a keypad or a telephone keypad (if 4285 or 4286 VIP module is used). Ask your installer if this has been done in your system.
  • Page 37: Event Log Procedures

    Event Log Procedures General Information To Display The Event Log The system has the ability to record 1. Enter CODE + [#] + [6] + [0] various events in a history log wherein 2. Select the display mode. each event is recorded in one of five RECENT: Displays only those events categories (listed below), with the time and occurring since last Event Log Clear...
  • Page 38 Event Logging Procedures (continued) 4. Use the [3] & [1] keys (for next and ALARM EVENT LOG previous categories respectively) to Displays time and date for zones that display the categories of events. have either caused an alarm or have been restored in the selected partition.
  • Page 39: Testing The System

    Testing The System (To Be Conducted Weekly) Using the 5 TEST Key The TEST key puts your system into Test mode, which allows each protection point to be checked for proper operation. 1. Disarm the system and close all protected windows, doors, etc. READY should be displayed.
  • Page 40: Fire Alarm System

    Fire Alarm System Your fire alarm system (if installed) is on 24 hours a day, providing continuous protection. In the event of an emergency, the smoke and heat detectors automatically send signals to your Control, triggering a loud interrupting sound from the keypad and the optional exterior sounders. FIRE appears at your keypad and remains on until you silence the alarm.
  • Page 41: Typical Trouble Displays

    Trouble Conditions Typical Trouble Displays The word CHECK on the Keypad’s display, accompanied by a rapid "beeping" at the Keypad, indicates that there is a trouble condition in the system. To silence the beeping sound for trouble conditions, press any key. •...
  • Page 42: Power Failure

    Trouble Conditions (cont’d) Power Failure If the POWER indicator is off, operating power for the system has stopped and is inoperative. CALL FOR SERVICE IMMEDIATELY. If the POWER indicator is on, but the message "AC LOSS" is displayed, the Keypad is operating on battery power only.
  • Page 43: Recommendations For Smoke And Heat Detectors

    Recommendations For Proper Protection The following recommendations for the location of fire and burglary detection devices help provide proper coverage for the protected premises. Recommendations For Smoke And Heat Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association’s (NFPA) Standard #72 noted below.
  • Page 44: Recommendations For Proper Intrusion Protection

    Recommendations For Proper Protection (cont’d) In addition, we recommend the following: ƒ Install a smoke detector inside every bedroom where a smoker sleeps. ƒ Install a smoke detector inside bedrooms where electrical appliances (such as portable heaters, air conditioners or humidifiers) are used. ƒ...
  • Page 45: Emergency Evacuation

    Emergency Evacuation Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association: 1. Position your detector or your interior and/or exterior sounders so that they can be heard by all occupants. 2.
  • Page 46: Maintaining Your System

    Maintaining Your System Taking Care of Your System The components of your security system are designed to be as free of maintenance as possible. However, there are some things you can do to make sure that your system is in reliable working condition. 1.
  • Page 47: Silencing Low Battery Warning Tones At The Keypad

    Maintaining Your System (cont’d) Silencing Low Battery Warning Tones at the Keypad The keypad’s warning tones can be silenced by performing an OFF sequence (code plus OFF key), but the Keypad's low battery message display will remain on as a reminder that you have a low battery condition in one or more of your sensors.
  • Page 48: Quick Guide To System Functions

    Quick Guide To System Functions FUNCTION PROCEDURE COMMENTS Check Zones Press [✱]. To view faulted zones when is system not ready Display All Press and hold [✱] for 5 seconds. Displays all alpha descriptors programmed by Descriptors installer. Arm System Enter code.
  • Page 49: Summary Of Audible Notification

    Summary Of Audible Notification (Alpha Display Keypads) SOUND CAUSE DISPLAY LOUD, FIRE ALARM FIRE is displayed; descriptor of zone in alarm is INTERRUPTED* displayed. Keypad & External LOUD, BURGLARY/AUDIBLE EMERGENCY ALARM is displayed; descriptor of zone in alarm is CONTINUOUS* ALARM also displayed.
  • Page 50 UL NOTICE: This is a “GRADE A” system. “FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT” This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception.
  • Page 51 “FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 NOTICE This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company.
  • Page 52 CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT NOTICE AVIS The Canadian Department of Communications label L’étiquette du ministère des Communications du Canada identifies certified equipment. This certification means identifie le matériel homologué. Cette étiquette certifie que that the equipment meets certain telecommunications le matériel est conforme à...
  • Page 53 WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons.
  • Page 54: Index

    Index #70 command ..........36 FCC...............50 4285 or 4286 VIP module ......8, 36 Fire............5, 34 AC Loss ............42 fire alarm ............40 Access Another Partition....... 20 Fire Protection..........6 Access Door..........35 GLOBAL ARM..........17 Add a User............ 17 Global Arming ..........20 ADD NEW USER ..........
  • Page 55 Quick Arm .............12 STAY .............31 Quick Arming..........14 STAY mode ...........26 Quick Bypass ..........25 System LO Bat ..........42 Quick Guide ..........48 System Overview..........5 Ready............22 Temporary Users...........17 READY............32 Test Key ............39 Ready Key.............22 Test mode .............39 Relay Menu Mode .........36 Testing Your System ........39 Replacing Batteries ........46 TRBL .............41 RF BUTTON..........17...
  • Page 56 ONE YEAR LIMITED WARRANTY Honeywell International Inc., 165 Eileen Way, Syosset, New York 11791, warrants its product(s) to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the...

Table of Contents