Test Report Code
*64
0 = disable; 1-F = see description above ∗59
Open Report Code
*65
0 = disable; 1-F = see description above ∗59
Arm Away/Stay Report Code
*66
0 = disable; 1-F = see description above ∗59
RF Low Battery Report Code
*67
0 = disable; 1-F = see description above ∗59
Cancel Report Code
*68
0 = disable; 1-F = see description above ∗59
Alarm Restores
*69
Send restore code (if fault cleared):
0 = at siren timeout (if restored) or at disarm
(whether restored or not)
1 = dynamically as the fault clears
2 = only after a disarm
Alarm Restore Report Code
*70
0 = disable; 1-F = see description above ∗59
Trouble Restore Report Code
*71
0 = disable; 1-F = see description above ∗59
Bypass Restore Report Code
*72
0 = disable; 1-F = see description above ∗59
AC Mains Restore Report Code
*73
0 = disable; 1-F = see description above ∗59
Low Battery Restore Report Code
*74
0 = disable; 1-F = see description above ∗59
RF Low Battery Restore Code
*75
0 = disable; 1-F = see description above ∗59
Test Restore Report Code
*76
0 = disable; 1-F = see description above ∗59

Miscellaneous System Fields

FIELD
TITLE and DATA ENTRIES
Summer Time
*77
Start/End Month
0 = Disabled
1 = Jan
2 = Feb
3 = Mar
Summer Time
*78
Start/End Weekend
0 = disabled
1 = first
2 = second
3 = third
4-6
Sent periodically to test that the communicator and phone lines are
operational. Frequency of report is set in Scheduling mode (event 11).
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
Sent upon disarming of the system in the selected partitions.
UL: Required for UL commercial burglar alarm installations.
This option allows for independent programming of Away and Stay
reports for each partition.
NOTE: "OPEN" reports are not sent if the associated closing report is
not enabled.
Sent when a wireless transmitter low-battery condition exists.
UL installations: must be enabled if wireless devices are used.
Sent upon disarming of the system after an alarm condition was
reported.
Alarm restore message will be sent upon condition selected.
Sent when an alarm zone is restored to its non-faulted condition or at
the times selected in field *69.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
Sent when a trouble in a zone is restored
UL: Required for commercial burglar alarm installations.
Sent when a zone that has been bypassed is unbypassed, either
manually or when the partition/system is disarmed.
UL: Required for commercial burglar alarm installations.
Sent when AC mains has been restored after an AC mains outage.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
Sent when a system low-battery condition is restored to normal.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
Sent when a transmitter's low battery condition is restored (i.e., new
battery installed).
UL installations: must be enabled if wireless devices are used.
Required for UL commercial burglar alarm installations and required
for residential fire alarm installations.
Sent when the Test mode is exited.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
EXPLANATION
Enter the start and end month for summer time, if applicable to the
region.
4 = April
# + 10 = Oct
# + 11 = Nov
# + 12 = Dec
Enter the start and end weekend for summer time, if applicable to the
region.
4 = fourth
5 = last
6 = next to last
7 = third to last