Honeywell ADEMCO VISTA-48A Installation And Setup Manual

Hide thumbs Also See for ADEMCO VISTA-48A:
Table of Contents

Advertisement

ADEMCO VISTA-48A
ADEMCO VISTA-48E
Security Systems
Installation and Setup Guide
K0749-1EN 11/04 Rev. A

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell ADEMCO VISTA-48A

  • Page 1 ADEMCO VISTA-48A ADEMCO VISTA-48E Security Systems Installation and Setup Guide K0749-1EN 11/04 Rev. A...
  • Page 2: Table Of Contents

    Table Of Contents • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Features and Installation Highlights ......................1-1 Capabilities ..............................1-1 Functions.................................1-1...
  • Page 3 Table Of Contents (continued) Menu Mode Programming..........................5-1 About Zone Programming (∗56 and ∗58 Menu Modes).................5-1 ∗56 Zone Programming Procedure.........................5-1 Completing Zone Programming ........................5-4 ∗58 Expert Programming Mode Procedures....................5-4 Wireless Key Programming Templates ......................5-6 About Output Device Programming (*79/*80 Menu Mode) .................5-8 *79 Menu Mode: Output Device Mapping .....................5-8 *80 Menu Mode: Defining Output Functions....................5-10 About Zone Lists (∗81 Menu Mode) ......................5-13...
  • Page 5: Features And Installation Highlights

    S E C T I O N Features and Installation Highlights • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • This manual describes the installation of both the VISTA-48A and VISTA-48E.
  • Page 6: Compatible Devices

    Installation and Setup Guide Compatible Devices • Supports up to 8 Addressable Keypads: 6148/6150 Fixed-Word Display Keypads, 6160/6164 Alpha Keypads, 6128RF/6150RF Keypad/Transceivers • Supports up to five 4219, 4229 addressable basic wired zone expander modules • Supports 5881/5883 series receiver and 5800 series transmitters •...
  • Page 7: Mounting And Wiring The Control

    S E C T I O N Mounting and Wiring the Control • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • This section describes the procedures for mounting and wiring this control and its peripheral devices.
  • Page 8: Mounting Board With Rf Receiver

    Installation Instructions Mounting Board with RF Receiver Notes • Do not mount the cabinet on or near metal a. Remove the receiver board from its case, then objects. This will decrease RF range and/or block insert the top of the board into the slots at the top RF transmissions from wireless transmitters.
  • Page 9: Wiring To Keypads

    Mounting and Wiring the Control Notes Wiring to Keypads • Typical Fixed-Word Display: Connect keypads to the control’s keypad terminals as 6128RF/6148/6150/6150V shown on the Summary of Connections diagram. • Typical Alpha Display: 6160/6160V/6164 Determine wire size using the Wiring Run Chart •...
  • Page 10: Sounder (Siren) Connections

    Installation Instructions Notes Sounder (Siren) Connections • The 12VDC sounder output activates when an 1. Make sounder connections to alarm output terminals 3 alarm occurs. (+) and 4 (–). • Total current drain from this output cannot For supervised output, continue with steps 2 and 3. exceed 2 amps (going beyond 2 amps will 2.
  • Page 11: Backup Battery

    Mounting and Wiring the Control Notes Backup Battery IMPORTANT: The panel will not power up 1. Place the 12-volt backup battery in the cabinet. initially on battery power only. You must plug the 2. After all connections to the control are completed and transformer in first, and then connect the battery.
  • Page 12: Basic Wired Zones

    Installation Instructions Notes Basic Wired Zones • EOLR: If the EOLR is not at the end of the loop, Normally Open Zones/Normally Open EOLR Zones the zone is not properly supervised and the system 1. Connect open circuit devices in parallel across the may not respond to an “open”...
  • Page 13: 4219/4229 Expansion Zones

    Mounting and Wiring the Control Figure 7. 4-Wire Smoke Detector Connections RELAY PROGRAM AUX PWR RELAY AUX PWR OUTPUT AS ZONE TYPE 54 TERMINALS POWER (FIRE ZONE TO OUTPUT 17 N.O. SUPERVISION RESET) PROGRAM OUTPUT 17 RELAY MODULE FOR "OUT NORM POWER N.C.
  • Page 14: 6164 Keypad Expansion Zones

    Installation Instructions Notes 6164 Keypad Expansion Zones • Each 6164 keypad supports up to 4 wired 1. Connect each keypad to the control’s keypad expansion EOLR or double-balanced zones and terminals. one relay output. If power supervision is required, use the Trigger •...
  • Page 15: Installing The Rf Receiver

    Mounting and Wiring the Control Notes Installing the RF Receiver • The receiver is supervised and a trouble report is Use one of the following receivers: sent (“CHECK 100” displayed) if communication RF Receiver Number of Zones between the panel and receiver is interrupted, or if 5881ENL up to 8 (including keyfob buttons) no valid RF signals from at least one supervised...
  • Page 16: Installing A Keyswitch

    Installation Instructions Transmitter Battery Life • See Wireless Transmitter paragraph in the Limitations of This Alarm System statement located at the end of this manual for information on transmitter battery life. • Some transmitters (e.g., 5802 and 5802CP) contain long-life but non-replaceable batteries, and no battery installation is required.
  • Page 17: Connecting Relay Modules

    Mounting and Wiring the Control Notes Connecting Relay Modules • Use 4204/4229 modules or 6164 keypad. 1. Mount either remotely or in the control panel. • Supervision: 4204/4229 modules and 6164 2. Connect to control’s keypad terminals using the keypad are supervised against removal. The connector harness supplied with the module.
  • Page 18: Powerline Carrier Devices

    Installation Instructions Powerline Carrier Devices Notes • When using Powerline Carrier devices, you must 1. Install up to 16 powerline carrier devices (if no relays use a Powerline Carrier Device Modulator. It are used) according to the instructions included with supplies signals from the control panel through each.
  • Page 19: Trigger Module And On-Board Triggers

    Mounting and Wiring the Control Trigger Module and On-Board Triggers Notes • The Trigger module (Trigger-G) provides IMPORTANT: Make all wiring connections to the Trigger supervision of auxiliary power and trigger Module before mounting the module to the PC board. power, and provides connections for the two 1.
  • Page 20: Phone Line Connections

    Installation Instructions Notes Phone Line Connections • If you are using an Audio Alarm Verification VISTA-48E (AAV) unit, refer to Audio Alarm Verification Connect incoming phone line and handset wiring to the (AAV) section for special wiring connections. main terminal block (via an RJ31X jack) as shown in the Summary of Connections diagram.
  • Page 21: Programming Overview

    S E C T I O N Programming Overview • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • About Programming You can program the system at any time, even at the installer's premises prior to the actual installation.
  • Page 22: Keypads

    Installation Instructions Keypads Keypads are identified by predefined addresses (starting at address 16) as follows: Address Keypad Program Field • always enabled for partition 1, all sounds enabled. keypad 1 NOTE: First keypad is address 16. • data field *190 keypad 2 •...
  • Page 23: Function Keys

    4. If using child-not-home pager report, define the report schedule using Scheduling mode (master code + [#] [6] [4] then select event type “03”). 5. If using a function key to manually send a message to a pager, see Function Keys paragraph below. 6.
  • Page 24 Installation Instructions • Assign to a zone covering a sensitive area such as a stock room, drug supply Type 05 Trouble when room, emergency exit door, etc. • Can also be used with a sensor or contact for an area where immediate Disarmed/ Alarm when Armed notification of an entry is desired.
  • Page 25 • Usually assigned to all sensors or contacts on windows and infrequently used Type 24 Silent Burglary exterior doors where siren sounding is NOT desired for alarms. • Provides an instant alarm, with NO audible indication at any keypad or external sounder, if the zone is faulted when the system is armed in the Away, Stay, Instant, or Maximum modes.
  • Page 26: Mechanics Of Programming

    Installation Instructions Mechanics of Programming To program the system from a keypad: • You must use a 2-line Alpha display keypad. • All partitions must be disarmed. Data Field Programming Procedures Task Procedure A) Press both [ ∗ ] and [#] at the same time within 50 seconds after power is applied to Entering Program Mode the control, B) After power-up, enter [Installer code (4-1-1-2)] + 8 0 0 (long beep indicates one of...
  • Page 27 Table of Device Addresses †† This Device Uses Address Reports as Enabled By… RF Receiver *56 zone programming: input device type entry AUI 1 automatic if AUI enable field *189 enabled for AUI 1 AUI 2 automatic if AUI enable field *189 enabled for AUI 2 Alternative Communication automatic if output to ACM field *29 enabled †...
  • Page 28 Installation Instructions...
  • Page 29: Data Field Programming

    S E C T I O N Data Field Programming • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • About Data Field Programming The following pages list this control’s data fields in numerical order.
  • Page 30: Zone Sounds & Timing

    Installation Instructions FIELD TITLE and DATA ENTRIES EXPLANATION Powerline Carrier Device (X-10) Powerline Carrier devices require a House ID, identified in this field. Program Powerline Carrier devices in interactive modes ∗79, *80 and House ID *81. 0 = A 6 = G # + 11 = L 1 = B 7 = H...
  • Page 31: Dialer Programming ( ∗ 40 - ∗ 50)

    Entry 1 for each partition selects whether arming from wired Confirmation Of Arming Ding keypads causes siren ding. Confirmation of arming is an external Entry 1: 0 = no; 1 = yes, 1-second ding sounder “ding” that follows the time selected in entry 2 for “ding at (ding if armed from wired keypad) Entry 2: Enter 0-15 from table below.
  • Page 32 Installation Instructions FIELD TITLE and DATA ENTRIES EXPLANATION Phone System Select/Dialer Phone System Select: Select the type of telephone service. Attempts Phone System Select: Dialer Attempts: Enter the number of times the system should If Central Station Receiver is not on satellite attempt to dial the central station, 1 –...
  • Page 33: System Status Report Codes

    Dynamic Signaling Priority Intended for use with Alternative Communication Media reporting. You must also enable field ∗29, ECP Contact ID Output for ACM. 0 = Primary dialer first; 1 = ECP Contact ID output first. Select the initial reporting destination for messages as follows: Primary Dialer First selected (0): •...
  • Page 34: Miscellaneous System Fields

    Installation Instructions Arm Away/Stay Report Code This option allows for independent programming of Away and Stay 0 = disable; 1-F = see description above ∗59 reports for each partition. NOTE: “OPEN” reports are not sent if the associated closing report is not enabled.
  • Page 35 FIELD TITLE and DATA ENTRIES EXPLANATION Linked Zone Verification Timer/ Linked Zone Verification Timer: Sets the maximum amount of time in which two linked zones must Up and About Timer be tripped in an armed system to send an alarm message to the Linked Zone Timer: Central Station.
  • Page 36 Installation Instructions FIELD TITLE and DATA ENTRIES EXPLANATION Miscellaneous Options Entry 1: Select the desired options by adding the values of each desired option. Entry 1 – AAV and Exit Delay Restart: 0 = none ††“Exit Delay Restart/reset” option allows use of the [∗] key to restart 4 = using Audio Alarm Verification (AAV) unit the exit delay at any time when the system is armed STAY or 8 = Enable Exit delay restart/reset ††...
  • Page 37: Pager Programming Fields

    Pager Programming Fields FIELD TITLE and DATA ENTRIES EXPLANATION Pager 1 Phone No. If you enter fewer than 20 digits, exit by pressing [∗] and next field *160 number. To clear entries from this field, press ∗160∗. Enter up to 20 digits Pager 1 Characters Up to 16 optional characters may be sent as a prefix to the 7-digit *161...
  • Page 38: Miscellaneous System Fields

    Installation Instructions Miscellaneous System Fields Select desired option. *173 RF REPORTING OPTIONS 0 = none 1 = RF Tamper reports during disarm 2 = RF keyfobs send low battery 3 = RF Tamper reports during disarm and RF keyfobs send low battery Tamper Options Select desired options.
  • Page 39 FIELD TITLE and DATA ENTRIES EXPLANATION Zone Bypass Limit Select the maximum number of zones that can be bypassed. *180 Each partition individually uses this entry. 0 = unlimited zone bypasses in each partition 1-7 = number of zone bypasses allowed in each partition 8 = zone bypass disabled (no zones can be bypassed)
  • Page 40: Keypad Programming Fields

    Installation Instructions Entry 1. If selected, will lockout the keypad for 15 minutes if 30 *188 Keypad Sabotage Options keystroke entries (6 attempts of code + command) are made without Entry 1: Keypad Lockout: a valid user code being detected. While the keypad is locked out, a 0 = disable;...
  • Page 41: Menu Mode Programming

    S E C T I O N Menu Mode Programming • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • About Zone Programming (∗...
  • Page 42 Installation Instructions PROMPT VALID ENTRIES EXPLANATION Zone Type (ZT) Each zone must be assigned to a zone type, which defines the way in 10 Zone Type which the system responds to faults in that zone. 00-24, 77, 82, 90-93 = zone Perimeter Enter the Zone Type code from the list below: type (see table at right)
  • Page 43 PROMPT VALID ENTRIES EXPLANATION Used only when enrolling wireless transmitters. Serial number Entry and 10 INPUT S/N: a. Transmit two open/close sequences. If using a button-type Loop Number Entry A 0 2 2 - 4 0 6 4 transmitter, press and release the button twice, but wait about 4 see explanation seconds before pressing the button the second time.
  • Page 44: Completing Zone Programming

    Installation Instructions Completing Zone Programming When you have finished programming all zones, test each zone using the system’s TEST mode. Do not use the Sensor Sniffer Mode for checking wireless transmitting devices, as it will only check for transmission of one zone on a particular transmitter, NOT the zones assigned to each additional loop.
  • Page 45 PROMPT VALID ENTRIES EXPLANATION Serial number Manually enter the serial number (found on the transmitter label), 10 INPUT S/N: by typing digits in the “X” locations, using the [A] (advance) or [B] S/N = serial number A XXX- XXX – (back) keys as required.
  • Page 46: Wireless Key Programming Templates

    Installation Instructions Wireless Key Programming Templates This procedure programs the wireless keys, but a key is not active until it is assigned to a user number (see System Operation section, assigning attributes command). If the D key was previously pressed (from *58 Menu mode) to enter and duplicate 5804 and/or 5804BD wireless keys, the following screens appear.
  • Page 47 Not Confirmed If the serial number transmitted does not match the serial number Entd A022-4063 entered, a display similar to the one shown will appear. If the loop [∗] to continue Rcvd A022-4064 number does not match, it will also be displayed. If so, activate the button on the wireless key once again.
  • Page 48: About Output Device Programming (*79/*80 Menu Mode)

    Installation Instructions About Output Device Programming (*79/*80 Menu Mode) Output Devices: The system supports up to 16 relays and/or Powerline Carrier devices (X-10 devices) plus 2 built-in trigger outputs in any combination. These 18 “outputs” are assigned to system-wide output numbers (01-18). Use *79 Menu Mode to assign output numbers and map them to device addresses.
  • Page 49 Start Output Device Mapping by pressing *79 while in Data Programming Mode. The following prompts are displayed: ∗ ∗ ∗ ∗ 79 Menu Mode PROMPT VALID ENTRIES EXPLANATION Device Output Number This is the logical (or reference) relay number as used in the system. ENTER OUTPUT NO.
  • Page 50: *80 Menu Mode: Defining Output Functions

    Installation Instructions *80 Menu Mode: Defining Output Functions Use this mode to program output function definitions (up to 48 functions) that provide automated control of any of the output devices, based on events occurring on individual zones or zones with certain zone types.
  • Page 51 Select where the initiating event for this output definition is to occur Activated By 01 Activated By: as follows: 0 = delete Zone List 0 = delete (deletes the output function and any previous 1 = zone list 2 = zone type programming;-see prompt below) 3 = zone number 1 = zone list (go to “A”...
  • Page 52 Installation Instructions “C” If zone number was selected, this screen appears. Zone Number 01 Enter Zn No. Enter the desired zone number associated with this output number. Press [∗] to continue. Enter the zone event that will activate this output. 01 Enter Event 0 = restore;...
  • Page 53: About Zone Lists (∗81 Menu Mode)

    About Zone Lists (∗ ∗ ∗ ∗ 81 Menu Mode) Zone lists let you group individual zones for use with certain system actions. The following table shows the available zone lists and their purposes: List No. Used for… 1, 2 general purpose chime-by-zone linked zones...
  • Page 54: About Function Key Programming (∗57 Menu Mode)

    Installation Instructions About Function Key Programming (∗ ∗ ∗ ∗ 57 Menu Mode) The system provides the ability to program each of the four keypad function keys to perform one of 12 system operations. The end user can then activate the function by simply pressing and holding the programmed key for 2 seconds.
  • Page 55: About Descriptor Programming (*82 Menu Mode)

    About Descriptor Programming (*82 Menu Mode) The system lets you directly enter zone descriptors for each protection zone so when an alarm or trouble occurs in a zone, an appropriate description for that zone's location can be displayed at the keypad. Each description is composed of up to 16 characters.
  • Page 56: Configurable Zone Type Programming (*83 Menu Mode)

    Installation Instructions Configurable Zone Type Programming (*83 Menu Mode) Start Configurable Zone Type Programming Mode by pressing ∗ 83 while in Data Programming mode. Zone Type Number Enter the configurable zone type number being programmed. E n t e r Z o n e T y p e 90-93 = zone type ( 0 0 = q u i t ) [∗] to continue...
  • Page 57 Display Options Select whether faults on zones assigned to this zone type are 9 0 D i s p O p t i o n displayed at the keypad and/or cause a chime sound. 0 = no display 1 = display only 2 = chime only 3 = chime &...
  • Page 58: Programming Installer And User Schedules

    Installation Instructions Programming Installer and User Schedules The system provides up to 32 schedules, which can be used to control various types of system events at pre-defined times. 24 schedules are intended for use by the end-user, and 8 are reserved for the installer.
  • Page 59 Start Time Enter the event’s start time and days of the week to occur. S T A R T S M T W T F S To select days, position the cursor under the desired days using the † 01-12 (00-23) = hour 0 0 1 0 0 0 0 H H M M A M...
  • Page 60 Installation Instructions 5-20...
  • Page 61: System Communication And Operation

    S E C T I O N System Communication and Operation • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Panel Communication with Central Station This system accommodates several formats for reporting alarms and other system conditions to the Central Station.
  • Page 62 Installation Instructions The following table lists codes for reports sent in different formats: Code for Code for Type of 3+1/4+1 3+1/4+1 Code for Report Standard Expanded 4+2/Robofon 8** Alarm SSS(S) A SSS(S) A SSSS (SS) AZ AAA(A) Z Trouble SSS(S) T SSS(S) T SSSS (SS) Tt TTT(T) t...
  • Page 63: Robofon 8 Format

    Robofon 8 Format send data in a pulsed frequency format in the following protocol: Robofon 8 format First bit Last Tone = 0, No tone = 1 Freq = 1000Hz ± 5Hz First Byte Last Byte ‘U’ 50 baud (20ms / bit) 200ms / char, 11 chars / message (‘U’...
  • Page 64: Ademco Contact Id

    Installation Instructions ® ADEMCO Contact ID ® ADEMCO and Robofon Contact ID Reporting takes the following format: CCCC(CCCCCC) Q EEE GG ZZZ where: CCCC(CCCCCC) = 4-digit or 10-digit Customer (subscriber) ID Q = 1-digit Event qualifier, where: E = new event , and R = restore EEE = 3-digit (hexadecimal) Event code (see central office receiver manual for a complete list of event codes) GG = 2-digit Partition Number (system messages show “00”)
  • Page 65: Security Codes

    Security Codes The system supports up to 48 security codes, which can each be assigned one of 5 authority levels. The authority level determines the functions each code can perform as follows: Authority Levels (authority levels can be assigned to users 3-49 only; users 1 and 2 cannot be changed) Level User No.
  • Page 66: Keypad Functions

    Installation Instructions Keypad Functions The following is a brief list of system commands. For detailed information concerning system functions, refer to the User's Manual. Keypad Commands Function Description Silence alarms Pressing any key will silence the keypad sounder for 10 seconds. Disarming the system will silence both keypad and external sounders.
  • Page 67: Follow-Me Feature

    Follow-Me Feature This feature lets users enter up to three phone numbers (system-wide) that the system will call in the event of an alarm in any partition at the protected premises, thus alerting the user to the alarm. • When an alarm occurs, the system reports the alarm to the central station (and pagers, if programmed), then, if programmed, dials the first follow-me phone number and proceeds as follows: 1.
  • Page 68: Various System Trouble Displays

    Installation Instructions Various System Trouble Displays Alpha Display Fixed Disp. Meaning CANCELED ALARM Appears if an exit or interior zone contained a fault during closing at the time the Exit Delay ended (e.g., exit door left open and the zone was not auto-bypassed), but the system was disarmed during the Entry Delay time.
  • Page 69: Testing The System

    S E C T I O N Testing the System • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • About Test Procedures After the installation is complete, you should perform the following tests: System Test:...
  • Page 70: Go/No Go Test Mode

    Installation Instructions NOTES: • All BR type RF units (e.g., 5804) must physically be activated to clear the display. • When one button of a transmitter (RF, UR, or BR) is activated, all zones assigned to other buttons on that transmitter are cleared. This also applies to multiple-loop transmitters (e.g. 5816 and 5817). •...
  • Page 71: Specifications & Accessories

    S E C T I O N Specifications & Accessories • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • SECURITY CONTROL 1.
  • Page 72 Installation Instructions Transformers: VISTA-48A: XF1 Model 60844CK, Ap11 V/99090/E148-36 VISTA-48E: 16.5VAC, 25VA wired-in transformer Sounders: Ademco AB-12M 25cm Motorized Bell & Box Ademco 1011BE12M 25cm Motorized Bell & Box Ademco 702 Outdoor Siren Ademco 719 2-Channel Siren Ademco 747 Indoor Siren Ademco 744 Siren Driver Ademco 745X3 Voice Siren Driver Ademco 705-820, 12.5cm Round Speaker...
  • Page 73: 5800 Series Transmitter Input Loop Identification

    5800 Series Transmitter Input Loop Identification All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the input loops requires its own programming zone (e.g., a 5804's four inputs require four programming zones). NOTE: For information on any LOOP 3 LOOP 2...
  • Page 74 Installation Instructions Compatible 5800 Series Transmitters Table (continued) Model Product Input Type Description Transmits a fault condition when temperature drops below 45°F. 5816TEMP Low-Temp. Sensor Has three unique input (loop) codes: one for a “Primary” contact 5817 Multi-Point Universal loop with programmable options; the others for two “auxiliary” Transmitter closed circuit contact loops.
  • Page 75 – NOTES –...
  • Page 76 Installation Instructions – NOTES –...
  • Page 77: Limitations And Warranty

    S E C T I O N Limitations and Warranty • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • WARNING THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced design security system, it does not offer guaranteed protection against burglary, fire or other...
  • Page 78: Installation Instructions

    Installation Instructions – INDEX – 1321 AC Transformer....1-2, 2-42-11 device address . 2-3, 2-7, 2-10, 3-1, 3-6, 4-2, 4- Panic Keys ..........7-3 1321X10......1-2, 2-4, 2-11, 9-2 11, 5-8, 7-3 Partitions..........3-1 24-Hour Audible Alarm......3-4 DIP Switches..........2-8 Perimeter Burglary........
  • Page 79 Figure 17. Summary of Connections...
  • Page 80: Limited Warranty

    Honeywell factory service. Connection of any device(s) to a communicating bus of a Honeywell security system (e.g., keypad bus, polling loop) other than those manufactured or approved by Honeywell shall void this warranty. For warranty service, return product(s) transportation prepaid to the nearest authorised distributor.