Installation Instructions

6164 Keypad Expansion Zones

1. Connect each keypad to the control's keypad
terminals.
2. Using the keypad's program mode, assign each
keypad a unique keypad address (16-23), and assign a
device address (07-11) from the following chart, based
on the zone numbers being used.
6164 Keypad Addresses
For Zones...Set Keypad to Device Address...
09-12
17-20
25-28
33-36
41-44
3. Connect sensors to the keypad's zone terminals.
4. If using the keypad relay, connect the desired field
wiring to the keypad's relay contact terminals.
See 6164 Keypad Instructions for other mounting,
wiring, and programming information.
2-8
07
(not available if zone-doubling enabled)
08
09
10
11
Notes
• Each 6164 keypad supports up to 4 wired
expansion EOLR or double-balanced zones and
one relay output.
• Use 2000 ohm end-of-line resistors at the end of
loops connected to the 6164 keypads.
• Enter 6164 keypad program mode by pressing
and holding down both the [1] and [3] keys
within 60 seconds of power up.
• Enable the keypad addresses using data fields
*191-*196 as required.
• Program keypad zones using *56 Menu mode.
Keypad zones 1-4 correspond to the respective
groups of zones shown in the chart at left, where
keypad zone 1 is the lowest zone number in each
group.
OPTIONAL
DOUBLE BALANCED
2K
TAMPER
2K
CONTACTS
TAMPER
2K
N.C.
CONTACTS
N.O.
C.
N.C.
Z1
Z2
(Z1
(Z3
&
&
Z2)
Z4)
CONVENTIONAL
EOLR
2K
[Y] DATA IN (<)
N.O.
[+] +12VDC IN
[-] GROUND (-12V)
[G] DATA OUT (>)
Y +
G
Z4
Z3