Biasi Riva ADVANCE SV Owner's Manual
Biasi Riva ADVANCE SV Owner's Manual

Biasi Riva ADVANCE SV Owner's Manual

Wall hung gas boiler for central heating supply

Advertisement

Quick Links

Riva
ADVANCE SV
WALL HUNG GAS BOILER FOR
CENTRAL HEATING SUPPLY
Please Read Instructions Carefully
Save for Future Reference
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property dam-
age, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor's phone. Fol-
low the gas supplier's instructions.
• If you can not reach your gas supplier call the fire department.
— Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
Quincy Hydronic Technology Inc.
3560 Lafayette Rd. Bldg. 2 Unit A
Portsmouth, NH 03801
Phone: 603-334-6400
Fax: 603-334-6401

Advertisement

Table of Contents
loading

Summary of Contents for Biasi Riva ADVANCE SV

  • Page 1 Riva ADVANCE SV WALL HUNG GAS BOILER FOR CENTRAL HEATING SUPPLY Please Read Instructions Carefully Save for Future Reference WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property dam- age, personal injury or loss of life. —...
  • Page 2 Thank you for buying a Biasi Riva Advance SV. central heat. We realize that it is not possible to answer all questions about the Riva Advance SV in this manual. Reading this installation manual does not make the reader an expert in all aspects contractor.
  • Page 3: Table Of Contents

    Table of Contents Section Title Section Number Page Number Warning Important Information General Information Technical Information Appliance Description Overview Control Panel Piping Connections LCD General Features 10-11 Instructions for Use 12-17 Warnings Refilling Procedure Lighting/Operating Instructions Temperature Unit Setting (°C or °F) Central Heating Circuit Temperature 14-15 Extinguishing Instructions...
  • Page 4: Warning

    WARNING Boiler is certified as an indoor appliance. Do not install boiler outdoors or locate where it will be exposed to freezing temperatures. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property dam- age, personal injury or loss of life.
  • Page 5 If any of the symptoms of CO occur, or if any of the signs of carbon monoxide are present, VACATE THE PREMISES IMMEDIATELY AND CONTACT A QUALIFIED HEATING SERVICE COMPANY OR THE GAS COMPANY OR THE FIRE DEPARTMENT. ONLY QUALIFIED, LICENSED SERVICE CONTRACTORS SHOULD PERFORM WORK ON YOUR BIASI RIVA ADVANCE SV BOILER. RIVA ADVANCE USER MANUAL...
  • Page 6: Important Information

    IMPORTANT INFORMATION Please read this page carefully. • ALL BOILERS MUST BE INSTALLED IN ACCORDANCE WITH NATIONAL, STATE AND LOCAL PLUMBING, HEATING AND ELECTRICAL CODES AND ORDINANC- ES, AS WELL AS THE REGULATIONS OF THE SERVING ELECTRICAL, WATER AND GAS UTILITIES. •...
  • Page 7: General Information

    1. General Information The Riva Advance SV is a high efficiency condensing, wall mounted gas boiler which provides central heat. The boiler features a gas valve which modulates the energy input from 32,000 BTU/h to 125,000 BTU/h. The boiler is shipped fully assembled. All units are pressure and combustion tested at the factory prior to shipping.
  • Page 8: Technical Information 2

    2. Technical Information Cont. ENERGY CAPACITY CLEARANCE TO COMBUSTIBLES Nominal heat input Front 125.0 (0/2000 ft) Back Nominal heat input 112.5 (2000/4500 ft) Sides 32.0 Minimum heat input Bottom Maximum useful output 112.5 (0/2000 ft) Flue pipe enclosed Maximum useful output Flue pipe free air 107.2 (2000/4500 ft)
  • Page 9: Appliance Description

    3. Appliance Description 3.1 Overview: 1 Case front panel 2 Control panel 3 Control panel cover 3.2 Control Panel: 4 Pressure gauge 5 LCD 6 Boiler reset /setting button 7 Function switch and Central heating tem- perature adjustment knob 8 Domestic hot water, temperature control knob 3 1 2 Figure 3.1...
  • Page 10: Lcd General Features

    4. LCD General Features The LCD (5 in Fig. 3.2) give detailed indication regarding the operation of the boiler. E04 + Faulty primary circuit (no water or absence of flow) E05 + Faulty fan control system E06 + Faulty c.h. temp. probe NTC E07 + Figure 4.1 Faulty d.h.w.
  • Page 11: Lcd General Features 4

    4. LCD General Features Cont. Set C.h. Boiler on demand for C.h. power (visible for 10 sec) (symbol flashing) (all other symbols are disabled) 25..85 (symbol flashing) 25..85 Default parameter reset. Boiler requesting heating power Reset is performed only by setting the cor- with external probe connected rect value and all symbols will turn on.
  • Page 12: Instructions For Use

    5. Instructions For Use 5.1 Warnings: • In order to guaranty safety and correct operation, it is essential that all the tests are carried out by a competent and responsible licensed service person before lighting up the boiler. • The tests are described in the installation, operation and service instructions manual in Sec- tion 15 Commissioning.
  • Page 13: Lighting/Operating Instructions

    5. Instructions For Use Cont. 5.3 Lighting/Operating Instructions: Warnings: Do not attempt to start the boiler unless all cleanout doors are secured and sealed. Do not attempt to light the burner by hand. 1 Check that the cocks connected to the gas inlet pipe and to the supply cold wa- ter inlet pipe (see section 3.3 for pipes) are open.
  • Page 14: Central Heating Circuit Temperature

    5. Instructions For Use Cont. 5.5 Central Heating Circuit Temperature: 1 Turn the selector 7 as in Figure 5.5. 2 The output temperature of c.h. water is adjustable from a minimum of about 100 °F to a maximum of about 185 °F (Figure 5.5), by turning the knob 7.
  • Page 15: Extinguishing Instructions

    5. Instructions For Use Cont. Adjustment: • In order to achieve optimal settings for From 41 to 59°F Between 23 and 41°F economy and comfort, we recommend adjusting the operating temperature of the central heating water according to the outside temperature, positioning the knob as in figure 5.7.
  • Page 16 5. Instructions For Use Cont. When you expect not to use the boiler for a long period: • Switch off the electricity supply to the boiler, by means of the circuit breaker; • Shut off the gas supply cock connected to the gas inlet pipe and the cock connected to the supply cold water inlet pipe (see section 3.3 for pipes);...
  • Page 17: Useful Advice

    6. Useful Advice 6.1 Central Heating: • For easy operation of the boiler, a room thermostat should be installed. • Never shut off the radiator in the area where the room thermostat is installed. • If a radiator (or a convector) does not heat up, check that no air is present in it and that its valve is open.
  • Page 18: External Cleaning

    6. Useful Advice Cont. 6.4 External Cleaning: • Before performing any cleaning, disconnect the appliance from the electrical mains, using the dedicated circuit breaker or serviceman’s switch located adjacent to the appliance. • To clean the external panels, use a cloth soaked in soapy water. Do not use solvents, abra- sive powders or sponges.
  • Page 19: Useful Advice 6

    6. Useful Advice Cont. If water comes out of the pressure relief valve pipe H in Fig. 6.4: • Check on the pressure gauge (figure 5.1 on page 12) that the pressure in the central heat- ing circuit is not close to 2 bars (30 psi). In this case, temperature rise in the circuit can cause the pressure relief valve to open.