Electrical data
Voltage
Frequency
Output at nominal heat input
Output at minimum heat input
Output in stand-by
Degree of protection
Heating/d.h.w. maximum gas flow rate
Methane G20
Propane G31
Minimum gas flow rate in heating mode
Methane G20
Propane G31
Minimum gas flow rate in d.h.w. mode
Methane G20
Propane G31
Max. gas pressure at the burner in heating mode
Methane G20
Propane G31
Min. gas pressure at the burner in heating mode
Methane G20
Propane G31
Ignition pressure
Methane G20
Propane G31
TECHNICAL SPECIFICATIONS
V ~
230
Hz
50
W
139
W
137
W
3
IPX5D
m
/h
3,59
3
kg/h
2,63
m
/h
1,64
3
kg/h
1,20
m
/h
1,64
3
kg/h
1,20
Pa
1200
mbar
12
Pa
3310
mbar
33,1
Pa
220
mbar
2,2
Pa
750
mbar
7,5
Pa
720
mbar
7,2
Pa
2320
mbar
23,2
Nozzles
Methane G20
Propane G31
Chimney design #
Max. flue gas temperature
Min. flue gas temperature
Max. flue gas mass flow rate
Min. flue gas mass flow rate
Max. air mass flow rate
Min. air mass flow rate
# Values refer to tests with 80 mm 1 + 1 twin pipe
discharge and Methane gas G20
Flue gas discharges
Boiler type
B22 C12 C32 C42 C52 C62 C82
Coaxial air/flue gas duct Ø
Twin pipe air/flue gas duct Ø
Coaxial air/flue gas duct to roof Ø
Other characteristics
Height
Width
Depth
Weight
Max. ambient temperature
Min. ambient temperature
G20 Hi. 34.02 MJ/m3 (15°C, 1013.25 mbar)
G31 Hi. 46.34 MJ/kg (15°C, 1013.25 mbar)
1 mbar corresponds to approx. 10 mm H20
(2307)
Ø mm
/100
15
130
15
78
°C
125
°C
114
kg/s
0,0196
kg/s
0,0205
kg/s
0,0190
kg/s
0,0205
mm
60/100
mm
80/80
mm
80/125
mm
703
mm
400
mm
325
kg
34,5
°C
60
°C
-15