All ports are temporarily disabled.
The packet LED is off.
The power LED is on.
The MGMT LED flashes until the switch successfully passes the POST.
If the switch passes the POST, the MGMT LED blinks at a slow rate (one blink per second). If the switch
fails the POST, the MGMT LED shows a solid yellow light.
700/1200 W AC PSU(s) come with both 110 V AC and 208/220 V AC power supply cords. The 110 V
AC power supply cord allows for a maximum DC output power of 700 W. The 208/220 V AC power
supply cord allows for a maximum DC output power of 1200 W.
All power supply cords provided by Extreme Networks are designed for use in the United States and
Canada only. Power supply cords for use outside of United States and Canada are typically provided
by a third party distribution center and must meet the following requirements:
Power supply cords must be agency certified for country of use.
Power supply cords must contain an IEC 320 C14 connector on the end of the PSU.
Power supply cords must contain an appropriate rated and approved wall plug applicable to the
country of installation.
Power supply cords must be less than 15 ft long.
Wire size must be a minimum of 16 AWG (1.0 mm
The 700/1200 W AC PSU line and neutral legs are both fused. Power to the chassis may still be live if
the neutral fuse is open. This is not a field operator replaceable fuse! In the event of failure, immediately
return the PSU for a complete replacement.
Operating conditions for the 700/1200 W AC PSU(s) are as follows:
Operating Temperature: 0°C to 40°C
Storage Temperature: -40°C to 70°C
Operating Humidity: 10% to 95% relative humidity, non-condensing
Operational Shock: 30 m/s
2
2
(3 g)
) copper stranded.