Run Time - UNI-T UTL8500X Series User Manual

Programmable dc electronic load
Table of Contents

Advertisement

Programable DC Electronic Load User Manual
Table 6-2 Description of Parameter Setting (UTL8512S)
Parameter setting

Run time

Delay on
Short time
V limit
I limit
P limit
V on
V off
V trigger
OVP
Digit filt
Trig select
Ripple
VPP limit
I rise
I fall
V rise
V fall
Power type
6.2.1 Run Time
If users set the single load time of the electronic load, no matter what mode it is running in,
the load will automatically stop loading after the set timing is reached. When this function
is not needed, set the parameter to 0.
Setting range
0~99999s
0~9999s
0.1~99999ms
0~150V
0~30A
0~300W
0~150V
0~150V
0~150V
ON/OFF
LV1/LV2/LV3/LV4
Trig/On/Off
Fast-V/Fast-I/Medium/Off
0~15V
0.001~30A/mS
0.001~30A/mS
0.010~15V/mS
0.010~15V/mS
Auto/CV/CC
Set the time for scheduled unload
Set the start time of delay
Set the time for short circuit test
Set the voltage value of over-voltage
protection
Set the current value of over-current
protection
Set the power value of over-power
protection
Set the load voltage at the beginning of
each run
Set the low voltage to automatically
end loading
Set the self-start voltage of the list
mode
Set whether to enable the overvoltage
protection function
Set the level of digital filter
Set the role of external trigger signal
input (function multiplexing)
Set the ripple sampling method, set the
hardware high-speed sampling voltage
ripple/current ripple
Set the protection value for excessive
ripple voltage
Set the current rising slope under load
Set the current fall slope under load
Set the voltage rise slope under load
Set the voltage fall slope under load
Set the type of power supply under test
64
Description