Programable DC Electronic Load User Manual
7. Press the ON button, the electronic load starts to load, and the indicator light below the
button lights up. If users want to suspend the test, they can press the [Pause] button. If
they need to stop the load, press the ON button again, and the running indicator light
goes out.
8. After the test is completed, users can press [Result] to view the test results. If the test
result is within the upper and lower limits, Pass will be displayed, otherwise Fail will be
displayed instead. Users can check whether each item is passed and save the test
record by taking a screenshot.
Note: The input data should not exceed the upper and lower limits of the current
parameters. When the data exceeds the parameter limits, they will not be saved, and the
cursor will stay in the grid. At this time, users need to clear or re-enter the appropriate
range of parameters. When users need to change the numbers in the list, click Delete to
clear the data in the table. After completing each parameter setting in the list, click the
Save button for easy calling next time.

4.2.3 Dual Mode

In order to meet more test requirements, the electronic load provides three dual modes:
CR+CC, CV+CR and CV+CC. Users can choose the appropriate mode according to the
actual situation. CR+CC can be used for power-on test, CV+CR can be used for setting
the Von point, and CV+CC can be used for battery discharge test.
Figure 4-2-2-2 Test Page of List Mode
30