Operation steps:
1. In initial interface, select [Mode], and then press [CP] to enter the setting interface of
<Constant Power CP>.
2. Move the cursor to power setting by pulse knob, and press the Enter button
change the power value (the value changes from yellow to white) by keyboard or
pulse knob. Press the Enter button
value changes from white to yellow.
3. Other parameters can be modified in a similar way.
4. Press the ON button, the electronic load starts to load, and the indicator light below
the button lights up. If users need to stop the load, press the ON button again, and the
running indicator light goes out.
Figure 4-1-4-2 Relationship of Voltage and Current in CP Mode

4.2 More Modes

To meet various test requirements, UTL8500X series electronic load offers more test
modes for choice, including Dynamic, List, Dual, OCP/OPP, CR-LED, Battery, Load Effect,
Figure 4-1-4-1 Setting Interface of CP Mode
Constant power
again to confirm. At this time, the set power
23