Non-Combustible Board Only (Painted Finish) - Regency Panorama P33CE Owners & Installation Manual

Zero clearance direct vent gas fireplace
Hide thumbs Also See for Panorama P33CE:
Table of Contents

Advertisement

6. If applying a non-combustible facing it may be installed over the metal surface of the firebox of the unit in the area shown below.

Non-Combustible Board Only (Painted Finish)

NON COMBUSTIBLE BOARD SUPPLIED WITH UNIT
Combustible and Non-combustible Facing and Finishing
NoTE: The 3-1/2" x 34-9/16" non combustible material supplied with this unit can be replaced if trying to achieve a clean finish. A large piece of non com-
bustible material (ie. 4' x 8' x 1/2") can be used to eliminate taped seams on or near unit.
7. Non-combustible material (ie. tile, slate, etc) may be brought up to the edge of the glass door of the unit. Minimum clearances must be adhered to, this
will assure ease of glass door removal and access to the lower panel.
NOTE: Non-combustible finishing materials may be of any thickness desired.
NON COMBUSTIBLE BOARD SUPPLIED WITH UNIT
No Combustible
Materials in this Area
NO FACING OR
FINISHING MATERIAL
IN THIS AREA
2-1/2"
[64mm]
Minimum Clearances for Finishing Materials
IMPORTANT FINISHING DETAIL NOTE:
Before placing unit into final position - it is important to know the
total thickness / height of finished hearth (tile, carpet, flooring etc.)
The Verona Surround or the Modera Mantel must be level to or higher
than the finished hearth height.
3-1/2"
[89mm]
34-9/16"
878mm
Materials around unit.
3-1/2"
[89mm]
5-3/16"
[132mm]
29-7/16"
747mm
34-9/16"
878mm
WOOD STUD
1/2" DRYWALL
DO NOT EXTEND
DRYWALL ONTO METAL
SURFACE OF UNIT.
NON-COMBUSTIBLE FACING
FOR CLEAN LOOK
(ie. PAINTED FINISH)
1/2" DRYWALL
Non-combustible
Finishing Material
Note:
All non-combustible facing material should butt up cleanly
to the flanges around the firebox opening.
Rough edges may be visible from an angle.
To maintain a clean finished edge - facing material edges
may be finished with a J-style trim or metal cornerbead (both
materials available at your local building or hardware store).
IMPORTANT: Materials used must be NON-COMBUSTIBLE.
Combustible
Material
Non-combustible Material (3-1/2" x 34-9/16")
Non-combustible
Nailing Strip -flush with unit
Finishing Material
Ensure finished
material is
brought to lip
Combustible
Material
No Combustible
Materials in this Area
J Style trim or metal
corner bead may be
used to finish edges
29-7/16"
747mm
Trim Materials
P33CE-11 Direct Vent Gas Fireplace
installation
Supplied with Unit
|
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Panorama 3ce-ng11Panorama 3ce-lp11

Table of Contents