WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach you gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
919-394b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
P33E Zero Clearance
®
P33E-LP10 Propane
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
6988 Venture St., Delta, BC Canada, V4G 1H4
Owners &
Installation Manual
P33 Video
www.regency-fire.com
06.29.16

Advertisement

Table of Contents
loading

Summary of Contents for Regency PANORAMA P33E

  • Page 1 Panorama P33E Zero Clearance Owners & ® Installation Manual Direct Vent Gas Fireplace P33 Video www.regency-fire.com MODELS: P33E-NG10 Natural Gas P33E-LP10 Propane WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
  • Page 2 The P33E-10 has been approved by Warnock Hersey/Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace.
  • Page 3 This appliance is only use with the type of gas indicated on the rating plate. This appliance is #8 Mobile Home Ground not convertible for use with other gases, unless a certified kit is used. P33 Video Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 4: Table Of Contents

    Burner & Log Assembly ..........55 Gas Line Installation ..........32 Vignette Faceplate And Finishing Trim ....56 Pilot Adjustment ............33 Safety Screen And Louvers ........57 High Elevation ............33 Warranty ..............58 Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 5: Safety Label

    The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 6: Ma Code - Co Detector

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 7: Unit Dimensions With Vignette Faceplate

    UNIT DIMENSIONS WITH VIGNETTE FACEPLATE Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 8: Unit Dimensions With Vignette And Vignette Finishing Trim

    UNIT DIMENSIONS WITH VIGNETTE AND VIGNETTE FINISHING TRIM UNIT DIMENSIONS WITH SAFETY SCREEN (#439-929) AND OPTIONAL LOUVERS Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 9: Important Message

    National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code. 3) See general construction and assembly in- Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 10: Manufactured Mobile Home Additional Requirements

    Safety screen and Optional Louvers 10) Final check. Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer. 10 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 11: Clearances With Vignette Faceplate

    59" (1499mm) carpeting, tile, etc. clearances are not adhered to. * see mantel clearance instructions. MANTEL LEG CLEARANCES WITH VIGNETTE FACEPLATE Combustible mantel leg clearances from side of unit as per diagram: Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 12: Combustible Mantels

    MANTEL CLEARANCES WITH VIGNETTE + VIGNETTE ONLY (No Vignette Finishing Trim) VIGNETTE FINISHING TRIM STEPPED FINISH MANTEL CLEARANCES WITH MANTEL CLEARANCES WITH VIGNETTE + VIGNETTE FINISHING TRIM SAFETY SCREEN AND LOUVERS FLUSH FINISH 12 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 13: Framing And Finishing

    6" (15cm) with AstroCap termination cap or is 6" (15cm) with AstroCap termination cap or 12" (30cm) with Rigid Vent termination cap. (For 12" (30cm) with Rigid Vent termination cap. (For example Dura-Vent). Example Dura-Vent). Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 14 6) Use steel studs for framing where the 1-1/2" (38mm) clearance from the vent to combustible material cannot be maintained. The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details. 14 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 15: Wall Mount On / Off Switch And Remote Receiver Installation

    11. Using the two (2) screws provided secure the cover plate to the Receiver. Low Voltage Junction Box Profl ame Receiver J-Box Receiver Slider Switch Wall Plate 10 ft. wire harness with 12 pin connector Diagram 1 Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 16: Unit Assembly Prior To Installation

    There are 5 vent systems approved for use with the P33-10: the Regency Direct Vent Flex System for Horizontal Terminations only and the Simpson Dura- ®...
  • Page 17: Exterior Vent Termination Locations

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 18: Regency ® Direct Vent Flex System

    Termination Caps Figure 1 Wherever necessary due to external location of cap, the AstroCap can be replaced with the FPI Riser Vent Termination Cap or the Dura-Vent Snorkel Termination Cap. 18 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 19: Installation Procedures

    2 x 4 or 2 x 6 walls. The liners must slip over the collars a minimum of 1-3/8". 6-7/8" Screws (175mm) (4 per connection) dia. air intake Wall Thimble 2 pieces (10" (254mm) Outer Diameter) Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 20: Rigid Pipe Venting Systems

    American Metal Products Ameri Vent Direct Vent, Security Secure Vent , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace ® Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. 20 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 21: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    4DT-FS 4DFSP 4DFS SV4BF TM-4CS Trim Plate-Black 4DT-TP 4DFPB 4DcP SV4LA TM-4TP Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 22 Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com 22 | Regency®...
  • Page 23: Rigid Pipe Venting Arrangements

    Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional rigid pipe adapter when using rigid vent systems (Part # 510-994). Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 24 Propane and Natural Gas. Maximum two 45 elbows allowed. • Vent must be supported at offsets. • Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. 24 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 25: Horizontal Terminations

    Maintain clearances to combustibles. • Horizontal vent must be supported every 3 feet. • Firestops are required at each floor level and whenever passing through a wall. Minimum Minimum Flex Kit Center-Line Simpson Dura-Vent Center-Line Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 26 3' Max. 4' Min. 6' Max. Please note minimum 4' Max. 6' Min. 7' Max. 1 foot between 90 5' Max. 8' Min. 8' Max. elbows is required. 26 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 27 1 foot between 90 required. elbows is required. 5' Min. 8' Max. 6' Min. 6' Max. 6' Min. For additional vertical venting with 2 x 90 elbows, refer to "Rigid Pipe Venting Arrangements" Section. Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 28 5' Max. 7' Min. horizontal. 5' Min. 6' Max. 8' Min. Please note min. 1 foot 6' Min. 7' Max. 9' Min. between 90 elbows is required. 7' Min. 8' Max. 10' Min. 28 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 29: Vertical Termination

    Masonry chimneys may take various contours which Outer Pipe with Kit# 946-563 Air Intake Pipe Length Co-Linear Flex Rigid Pipe Adapter Adapter # 510-994 with Kit# 946-563 45 Elbow Inner Pipe Adapter with Kit# 946-563 Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 30: Venting Arrangements - Vertical Terminations

    VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. 30 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 31: Unit Installation With Horizontal Termination

    “Mill- pipe. clearances. Pac” sealant (supplied) to every inner pipe connection. Failure to do so may result in drafting or performance issues not covered under warranty. Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 32: Unit Installation With Vertical Termination

    Diagram 2 8) Install the vertical termination cap by twist- 32 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 33: Pilot Adjustment

    885 S.I.T. VALVE DESCRIPTION 1) 6 Stage flame adjustment 2) Pilot adjustment 3) Inlet Pressure Tap 4) Outlet Pressure Tap 5) Pilot Outlet 6) Main Gas Outlet 7) Main Gas Inlet Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 34: Conversion From Ng To Lp

    Remove burner orifice with a 1/2" wrench and discard. Use another wrench to hold on to the elbow behind Remove the 2 screws holding the Burner the orifice. Assembly to the firebox base. Push the Installer Notice: Burner Assembly to the left and lift out. These instructions must be left with the appliance. 34 | Remove the 2 screws, push Burner Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace Assembly to the left and lift out.
  • Page 35: Optional Brick Panels

    5) Slide the Top Brick Panel into position and slide the Top Brick Retaining clips so that they hold the Top Brick Panel in place and tighten down the screws. 2nd Grate Tab Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 36: Standard Flush Door

    See Diagram 2. 5th Grate Tab 36 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 37: Vignette Faceplate And Safety Screen Installation

    Vignette frame (see below). Screen below. assembly is secured at bottom with magnets. Screen Assembly Vignette Frame Reverse Steps to remove. Secure Vignette frame using 2 screws in locations shown below. Final Install Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 38: Optional Vignette Finishing Trim Install

    Hook Vignette Faceplate brackets into place. Line up the screw holes on the fi nishing trim and Vignette Face- plate bracket with the unit–fasten with one screw on each side– P33 only. 05.04.15 919-566 38 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 39: Optional Vignette Inlay Installation

    Inlay through the actual screen. NOTE: Ensure Inlay is in correct position before pushing studs through the safety screen. Stud Nut + washer (supplied) Completed Install Line up Inlay–Push studs on Inlay through screen Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace 05.21.15 919-559...
  • Page 40: Optional Finishing Trim

    Line up the screw holes on the finishing trim and Vignette Faceplate bracket with the unit–fasten with one screw on each side. Reinstall the glass door and safety screen. Finishing Trim Top Finishing Trim Side 40 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace 10.29.14 919-475...
  • Page 41: Optional Louvers

    Loosen the screws–slide deflector on and tighten screws. allow access to attach bottom louver brackets to unit with one screw on each side in locations shown below. Magnet locations 07.21.15 919-558a Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 42: Wiring Diagram

    Caution: Ensure that the wires do not touch any CAUTION: Label all wires prior to disconnection hot surfaces and are away from sharp edges. when servicing controls. Wiring errors can cause improper and dangerous operation. 1 of 10 42 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 43: Optional Wall Thermostat Installation

    When complete turn remote receiver to the ON position. Unit will now operate using the wall thermostat. NOTE: When the remote receiver is set to ON position, the remote control transmitter and all of its features are now dis- abled. Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 44: Optional Fan Installation

    THESE FANS COLLECT A LOT OF DUST FROM WITHIN YOUR HOME. ENSURE YOU MAINTAIN THESE FAN MOTORS ON A REGULAR BASIS BY VACUUMING THE FAN BLADES AND THE HOUSING WITH A SOFT BRUSH NOZZLE. 44 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 45: Ac Power Adaptor Installation (For Surefire Systems)

    2. Tuck any loose wires neatly underneath the firebox–inside the fireplace. Note: Ensure that wires do not touch the underside of the fire box (Keep wires away from heat as much as possible). AC adaptor Wire adaptor Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace 10/09/14 919-063...
  • Page 46: Wiring Diagram With Optional Fan

    Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. 46 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 47: Lighting Procedure

    2. Press and release the ON/OFF button on the remote handheld transmit- to the unit. ter (see Diagram 2). An audible beep should be heard from the receiver. ON/OFF Button Diagram 2 Remote shown in Manual Mode on Hi Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 48: Copy Of The Lighting Plate Instructions

    Utiliser l'interrupteur mural ou la télécommande pour mettre le système sur ON/OFF. Appuyer sur la touche ''OFF'' de la télécommande. Mettre le bouton de commande de gaz sur ''OFF'' pour éteindre la veilleuse. DO NOT REMOVE THIS INSTRUCTION PLATE 919-401 48 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 49: Operating Instructions

    The glass should be cleaned or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and NEVER clean the glass while it is hot. Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 50: Maintenance Instructions

    "cracking" and "ticking" sounds will be severely alter the unit's performance heard throughout the cycling process. which is not covered under warranty. GLASS GASKET 50 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 51: Glass Gasket

    WARNING: Do not operate the appli- ance with the glass panels removed, cracked or broken. Replacement of Flush Glass Replacement Remove the flush door front. Remove the 4 glass clips from each corner. Slide in the new Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 52: Removing Valve

    6) Disconnect the Electronic modulator, EV1, EV2, and ground wires from the valve - as shown below. INSTALLING VALVE Ground 1) Install new valve assembly. 2) Reverse steps 9 through 1. Electronic Modulator 52 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 53: Main Assembly

    Brick Panel - Rear 510-994 Rigid Pipe Adaptor Brick Panel - Left Side 919-394 Manual Brick Panel - Right Side Brick Panel - Top *Not available as a replacement part. 430-056 Brick Clip - Top Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 54: Parts List

    HEAT WAVE DUCT KIT #946-556 BRICK PANEL SET FAN ASSEMBLY 54 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 55: Burner & Log Assembly

    Remote transmitter (GTMF) 910-127 Battery compartment door 911-037 Flame sense 911-038 Flame electrode 911-039 Pilot hood 911-432 Pilot tubing 911-137 Pilot clip 911-030 Fan control module *Not available as a replacement part. Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 56: Vignette Faceplate And Finishing Trim

    Vignette Door Inlay Black Chrome 439-924 Vignette Faceplate Black 439-949 Vignette Door Inlay Mt. Black 439-926 Vignette Faceplate Tuscan Sunset 439-950 Vignette Door Inlay Tuscan Sunset Parts Not Shown 430-940 3 sided Finishing Trim 56 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 57: Safety Screen And Louvers

    SAFETY SCREEN AND LOUVERS Part # Description 430-922 Flush louvers black 439-929 Safety Screen Regency Logo Plate 948-216 ® Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 58: Warranty

    The purchase price must be confirmed by the original Bill of Sale. 58 | Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 59 Minor movement, expansion and contraction of the steel is normal and is not covered under the terms of this warranty. Freight damages for products or parts are not covered under the terms of the warranty. Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace...
  • Page 60 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
  • Page 61 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 64 Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ P33 Video Regency, Panorama, AstroCap and Surefire are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2016, FPI Fireplace Products International Ltd. All rights reserved.