operating instructions

Operating
Instructions
1) Read and understand these instructions before
operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is properly
positioned. Never operate the appliance with
the glass removed.
5) Verify that the venting and cap are unobstructed.
6) Ensure that the brick panels are installed.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have been
incorrectly positioned.
8) The unit should never be turned off, and on
again without a minimum of a 60 second wait.

First Fire

The first fire in your fireplace is part of the paint
curing process. To ensure that the paint is properly
cured, it is recommended that you burn your fireplace
for at least four (4) hours the first time you use it
with the fan on.
When first operated, the unit will release an odour
caused by the curing of the paint, the burning off
of any oils remaining from manufacturing. Smoke
detectors in the house may go off at this time.
Open a few windows to ventilate the room for a
couple of hours.
The glass panel may require cleaning after the unit
has cooled down. DO NOT ATTEMPT TO CLEAN
THE GLASS WHILE IT IS HOT.
Note: When the glass is cold and the
appliance is lit, it may cause
condensation and fog the glass.
This condensation is normal and
will disappear in a few minutes as
the glass heats up.
DO NOT BURN THE APPLIANCE WITH-
OUT THE GLASS FRONT IN PLACE.
During the first few fires, a white film may
develop on the glass front as part of the cur-
ing process. The glass should be cleaned or
the film will bake on and become very difficult
to remove. Use a non-abrasive cleaner and
NEVER clean the glass while it is hot.
|
56
P33CE-11 Direct Vent Gas Fireplace
Aeration
Adjustment
The air shutter can be adjusted by moving
the adjusting wire up or down. The wire is
accessed through the bottom opening. Open
the air shutter for a blue flame or close for a
yellower flame. The burner aeration is factory
set but may need adjusting due to either the
local gas supply or altitude.
Minimum Air Shutter Opening:
3/16" Natural Gas - Orifice # 44
3/8"
Propane -
Orifice # 54
CAUTION: Carbon will be produced if air
shutter is closed too much.
Obturateur
d'air
câble
Câble de réglage: pousser pour
fermer ou tirer pour ouvrir
Closed - Tall yellow
Open - Short blue
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT
covered under warranty.
Note: Aeration Adjustment should only
be performed by an authorized
Air
shutter
Regency
Installer at the time of
®
installation or service.
wire
Adjustment Wire: push to close
or pull to open aeration cap