Regency Panorama P33CE Owners & Installation Manual page 28

Zero clearance direct vent gas fireplace
Hide thumbs Also See for Panorama P33CE:
Table of Contents

Advertisement

installation
Description
Attic Insulation Shield 12"
Attic Insulation Shield
- Cold Climates 36"
Basic Horizontal Termination Kit (A)
Horizontal Termination Kit (B)
Vertical Termination Kit
High Wind Vertical Cap
High Wind Horizontal Cap
Horizontal Square Termination Cap
Vertical Termination Cap
Storm Collar
Flashing - Flat Roof
Adjustable Flashing 0/12-6/12
Adjustable Flashing 6/12-12/12
Vinyl Siding Standoff
Vinyl Siding Shield Plate
Snorkel Termination 14"
Snorkel Termination 36"
Wall Firestop
* Not available from Regency
***Olympia Ventis DV application for the following units only when using 4" x 6-5/8" vent system: B36XTE, B36XTCE, all City Series 40 models, CV72E/CB72E (power-
vented models only), G600C, G600EC, G800C, G800EC, P36, P36E, RC500E.
FPI
946-506/P
Vent Guard (Optional) for AstroCap
**510-994
Rigid Pipe Adaptor (Must use with all rigid piping)
640-530/P
Riser Vent Terminal
**The rigid pipe adaptor is not required on the C34, C34E, U39, U39E, H15, H27, H35 & RC500E.
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
Run (X)
0" (0mm)
4-7/8" (124mm)
6" (152mm)
8" (203mm)
9" (229mm)
10-1/8" (257mm)
12" (305mm)
12-1/4" (311mm)
24" (610mm)
20-5/8" (524mm)
36" (914mm)
29" (737mm)
48" (1219mm)
37-7/16" (951mm)
Note: Horizontal runs of vent must be level, or have a 1/4" rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high temperatures and may present a possible fire hazard.
|
28
P33CE-11 Direct Vent Gas Fireplace
*Selkirk
Simpson
Direct Temp™
®
Direct Vent Pro
46DVA-IS
N/A
46DVA-KHA
N/A
N/A
4DT-HKA
N/A
4DT-HKB
N/A
4DT-VKC
46DVA-VCH
N/A
N/A
N/A
46DVA-HC
4DT-HHC
46DVA-VC
4DT-VT
46DVA-SC
4DT-SC
46DVA-FF
N/A
46DVA-F6
4DT-ST14
46DVA-F12
4DT-ST36
46DVA-VSS
4DT-VS
N/A
4DT-VSP
46DVA-SNK14
N/A
N/A
N/A
46DVA-WFS
N/A
4" x 6-5/8" Venting
Rise (Y)
13-7/8" (340mm)
16-1/2" (419mm)
18-5/8" (473mm)
20-3/4" (527mm)
29-1/8" (740mm)
37-1/2" (953mm)
45-15/16" (1167mm)
*American Metal
*Metal-Fab™
Products®
Sure Seal
Amerivent Direct
4DAIS12
4DIS
4DAIS12
N/A
4DHTK2
4DHTKA
4DHTK1
4DHTKB
4DHTK
4DHTK
N/A
N/A
N/A
N/A
4DHC
4DHT
4DVC
4DVT
4DSC
4DSC
N/A
N/A
4D12S
4DF
4D36S
4DF-12
N/A
4DVS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
946-205
Vinyl Siding Shield for Riser Vent Terminal
946-208/P
Vent Guard (Optional) for Riser Vent Terminal
946-523/P
AstroCap Horizontal Cap
946-206
Vinyl Siding Standoff for AstroCap
For specific instructions on venting components - visit the
manufacturers website listed below.
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
American Metal Products: www.americanmetalproducts.com
Metal-Fab Sure Seal: www.mtlfab.com
Security Secure Vent: www.securitychimneys.com
Industrial Chimney Company: www.icc-rsf.com
Olympia Ventis DV: www.olympiachimney.com
*Security
*ICC Excel
Secure- Vent®
Direct
SV4RSA
N/A
N/A
TM-4AS
SV-SHK
TM4-HTK
SV-HK
TM4-HTK
SV-FK
N/A
N/A
TM-4VT
N/A
TM-4DHT
SV4CHC-1
TM-4HT
SV4CGV-1
N/A
SV4FC
TM-SC
N/A
N/A
SV4STC14
TF-4FA
SV4STC36
TF-4FB
SV4VS
TM-VSS
SV4VS
N/A
N/A
TM-4ST14
N/A
TM-4ST36
N/A
TM-4TR
*Olympia
Ventis DV***
VDV-AIS04
N/A
VDV-KW04
VDV-K04
N/A
VDV-VCHW04
N/A
VDV-HC04
N/A
VDV-SC04
N/A
VDV-F0406
VDV-SSO
N/A
N/A
N/A
N/A
VDV-FS04

Advertisement

Table of Contents
loading

This manual is also suitable for:

Panorama 3ce-ng11Panorama 3ce-lp11

Table of Contents