Regency P33R-LP2 Owners & Installation Manual

Zero clearance rear direct vent gas fireplace
Table of Contents

Advertisement

P33R Zero Clearance Rear Direct Vent
WARNING:
If the information in these instructions are not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Tested by:
918-063a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
www.regency-fire.com
Gas Fireplace
MODELS:
P33R-NG2 Natural Gas
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Installation Manual
P33R-LP2 Propane
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
Owners &
04/26/04

Advertisement

Table of Contents
loading

Summary of Contents for Regency P33R-LP2

  • Page 1 Owners & Installation Manual Gas Fireplace MODELS: P33R-NG2 Natural Gas P33R-LP2 Propane WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fire or explosion may result causing property damage, Do not try to light any appliance personal injury or loss of life.
  • Page 2 Regency Fireplace. INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: ANSI Z21.44- 1995, CAN1-2.19-M81, CAN/CGA-2.17-M91 and ANSI Z21.88-1998/CSA 2.33-M98.
  • Page 3: Table Of Contents

    Optional Bay Trim ............. 24 Louvers - Bay ............25 Remote Control (optional) .......... 25 Wall Thermostat (optional) ........25 Remote Wall Switch ..........25 Wiring Diagram ............26 Optional Fan Installation ..........27 Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 4: Safety Label

    For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length. For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 5: Installation

    OF HIGH SURFACE TEMPERA- 9) Wear gloves and safety glasses for pro- TURES, ESPECIALLY THE FIRE- tection while doing required maintenance. PLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 6: Installation Checklist

    4) The P33R-2 Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C, D. See Dia. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 7: Clearances

    Combustible mantel leg clearances as per diagram below: Maximum 1-1/2" projection at 2" minimum clearance. The HeatWave Duct Kit has different clearance and framing requirements, Clearances for Bay or Flush Front check the HeatWave manual for details. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 8: Framing And Finishing

    NOTE: If this is an outside corner, the minimum son Dura-Vent). distance between the vent and the outside corner is 6" (15cm) with AstroCap termination cap or 12" (30cm) with Dura-Vent termination cap. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 9: Unit Assembly Prior To Installation

    2) Use the same screw hole position for the Side Nailing Strips as was used for the Top Facing Support. Attach each side nailing strip using 3 screws. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 10: Exterior Vent Termination Locations

    INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 11: Venting Introduction

    There are 2 vent systems approved for use with the P33R-2: the Regency Direct Vent System (Flex) for Horizontal Terminations only (see pages 11-12), and the Simpson Dura-Vent Systems for Horizontal and Vertical Terminations (see pages 13-19).
  • Page 12: Venting - Installation Of Regency Direct Vent System (Flex)

    The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls. The liners must slip over the collars a minimum of 1-3/8". Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 13: Venting - Simpson Dura-Vent System

    Termination Cap 946-205 Vinyl Siding Shield for Riser 904B 24" Pipe Length - Black Vent Terminal 36" Pipe Length - Galv. 946-523/P AstroCap Termination Cap 903B 36" Pipe Length - Black Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 14: Venting Arrangements - Horizontal Terminations

    A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. For horizontal terminations the Regency Direct Vent Flex System (see page 10) may be used for installations with a maximum continuous vent length of 10 ft (3.0m).
  • Page 15: Venting Arrangements - Vertical Terminations

    Firestops are required at each floor level and whenever passing through a wall. • Maintain a 1-1/4" clearance to combustibles Note: Must use optional flue adapter when using Simpson Dura-Vent pipe (Part # 510-994). Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 16: Vertical Terminations - Co-Linear Flex System

    Vertical Termination Cap High Wind Cap 923GK 3" Co-linear Adapter with flashing FPI Cabinet and/or Flat Wall Mantles may be used in these applications ensuring that clearances to com- bustibles are maintained. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 17: Venting Arrangements

    INSTALLATION Venting Arrangements - Vertical Terminations with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 18: Venting - Horizontal Installations

    8) Slide the appliance and vent assembly to- ry twist-lock joint. wards the wall carefully inserting the vent Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 19: Venting - Vertical Termination

    Flare nuts for copper lines and flex Diagram 2 seal with a mastic. connectors are usually considered to meet this requirement. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 20: Pilot Adjustment

    2) Manual high/low adjustment 3) Pilot Adjustment 4) Thermocouple Connection - option 5) Outlet Pressure Tap 6) Inlet Pressure Tap 7) Pilot Outlet 8) Main Gas Outlet 9) Alternative TC Connection Point Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 21: Conversion To Propane

    18) Check operation of flame control. the new screws (E) supplied with the kit. Tighten screws securely. 19) Check for proper flame appearance and glow on logs. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 22: Optional Brick Panels

    A) 02-57 slide the Top Brick Retaining clips so that A) 02-57 they hold the Top Brick Panel in place and tighten down the screws. B) 02-61 2nd Grate Tab Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 23: Flush Door - Standard

    B) 02-61 attach trim to the top and bottom of Flush door. 5th Grate Tab A) 02-57 D) 02-58 B) 02-61 Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 24: Louvers - Flush

    2) Secure to the flush door bottom bracket with 2 screws provided. 3) Slide the valve extension knobs onto the valve knobs. Burner ON/OFF control box attached to bottom flush louver. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 25: Louvers - Bay

    Wire Size Max. Length to 120V wire. 14 GA. 50 Ft. 16 GA. 32 Ft. 18 GA. 20 Ft. 20 GA. 12 Ft. 22 GA. 9 Ft. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 26: Wiring Diagram

    Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 27: Optional Fan Installation

    Push hold-down clip onto inside ing using a soft brush nozzle. louver and press tab until it is at louver. Diagram 1 Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 28: Lighting Plate Instructions

    “OFF”. Do not force. appliance if service is to be performed. You may shut off the pilot during prolonged non use periods to conserve fuel. DO NOT REMOVE THIS INSTRUCTION PLATE 908-017a Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 29: Operating Instructions

    Use a non-abrasive cleaner and NEVER clean 6) Rotate the flame height regulator to adjust the glass while it is hot. the flame height higher or lower. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 30: Normal Operating Sounds Of Gas Appliances

    Vent. Remove any bird nests, or other foreign material. 3) Check for evidences of excessive conden- sation, such as water droplets forming in the inner liner, and subsequently dripping Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 31: Thermopile/Thermocouple

    Re- placement of the glass panels should be done by a licensed or qualified service person. Caution: Wear gloves when remov- ing damaged or broken glass. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 32: Removing Valve

    17) Close the door and replace the louvers. 18) Fire up the unit again and check for proper flame appearance and glow on logs. Valve Tray Assembly screws Diagram 2: Rear Log Stand & Valve Tray Assembly Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 33: Parts List

    49) 910-142 Thermodisc - Fan Auto ON/OFF *Not available as a replacement part. 50) 904-713 U-Clip at Louver 432-967 Burner On/Off Switch Assy 63) 910-241 Switch - Burner On/Off 910-899 Wire Harness - Valve to Burner Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 34 Burner Assy - NG/LP 430-100 Burner Grate Assembly - NG/LP Rear Log Support Bracket - NG/LP 431-930 Log Set 430-097 Air Deflector-Left 430-098 Air Deflector-Right *Not available as a replacement part. Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 35 U-Clip 139) 936-155 Glass Gasket (Tadpole) 179) 948-216 Regency Logo Plate 140) 948-042 Spring Hinge - Black *Not available as a replacement part. 430-940 Finishing Trim (Set) - Black (Option) Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 36 432-956 Bay Door Trim (set) - Gold 432-954 Bay Door Trim (set) - Brass 432-958 Bay Door Trim (set) - Brushed Steel 123) * Bay Door Trim (each) - Black Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 37 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ _________________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________________________________ ___________________________________________________________ __________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________________________________ __________________________________________________________ __________________________________________________________ _____________________________________________________ ________________________________________________________ _________________________________________________________ _________________________________________________________ Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 38 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ _________________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________________________________ ___________________________________________________________ __________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________________________________ __________________________________________________________ __________________________________________________________ _____________________________________________________ ________________________________________________________ _________________________________________________________ _________________________________________________________ Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace...
  • Page 39: Warranty

    Regency Fireplace Products, are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.
  • Page 40 Dealer Name & Address: ______________________________________________ __________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: _________________________________________________________ Regency and Panorama are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2004, FPI Fireplace Products International Ltd. All rights reserved.