Regency P33 SunriseTM P33S-LP4 Specifications

Regency p33 sunrise gas fireplace specifications sheet

Advertisement

Quick Links

Model
Fuel Type
Minimum Supply Pressure
5" W.C. (1.25 kPa)
Manifold Pressure - High
3.5" W.C. (0.87 kPa)
Manifold Pressure - Low
1.6" W.C. (0.39 kPa)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
Vent Sizing
4" Inner / 6 5/8" Outer
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems:
Simpson Direct Vent Pro®
American Metal Products® Amerivent Direct
Security Secure Vent®
Selkirk Direct-Temp™
Metal-Fab® Sure Seal
Unit Dimensions
Description
A
Front Face Width
B
Rear Firebox Width
C
Front Face Height
D
Height w/ Standoff
E
Unit Depth
F
Firebox Height
Framing Dimensions
Description
G
Framing Width
**
**
H
Framing Height
*
I
Framing Rise from Floor
Vertical
Framing
J
Depth
Horizontal
K
Corner Wall Length
L
Corner Facing Wall Width
M***
Framed Chase Ceiling***
N
Vent Centerline Height
* The unit must be raised a minimum of 1" above the fi nished fl oor.
** Dimension H = H + I (minimum)
*** Dimension M = M + I (minimum)
This manual is intended to be a Sales Reference Guide only.
Do NOT use for actual framing and installation of any unit.
Some specifi cations may change without notice.
You must use the actual manual for exact installation specifi cations.
Regency P33 Sunrise Gas Fireplace
P33S-NG4
P33S-LP4
Natural Gas
Propane
11" W.C. (2.73 kPa)
10" W.C. (2.49 kPa)
6.4" W.C. (1.59 kPa)
17,000 BTU/h
15,500 BTU/h
(4.98 kW)
(4.54 kW)
4" Inner / 6 5/8" Outer
P33S
33-5/8" (846mm)
23" (584mm)
29" (737mm)
31 1/2" (800mm)
12-3/4" (324mm)
29" (737mm)
P33S
33-1/4" (845mm)
**
31-3/4" (806mm)
*
1" (25mm) minimum
19 -1/2" (495mm) Vertical Rise
16 1/2" (419mm) Rigid
12-3/4" (324mm) Flex
37 -1/2" (953mm)
53-1/4" (1353mm)
36" (914mm) Rigid***
32" (813mm) Flex***
30" (762mm) Rigid
26" (660mm) Flex
Regency P33 Sunrise Gas Fireplace
Dimension
Description
O
Gas Connection Height
P
Gas Connection Inset
Q
Gas Connection Width
R
Minimum Framing Depth
Maximum Framing Depth
S
(including wall thickness)

Clearance Requirements

Clearance:
Dimension
A: Rise
1" minimum
B: Sidewall
7-1/2"
C: Ceiling
30"
D: Alcove Width
48"
E: Alcove Depth
36"
WARNING
Failure to maintain required clearances is a major cause of chimney related fi res.
Installation of this fi replace must comply with these clearances
Please note: Due to ongoing product development, product appearance and specifi cations
are subject to change without notice.
P33 Sunrise Gas Fireplace
P33S
1-1/2" (38mm)
4" (102mm)
3" (76mm)
16 1/2" (419mm) Rigid / 12-3/4" (324mm) Flex
40 1/2" (1028mm) Rigid / 36-3/4" (933mm) Flex
C
B
Close to Ceiling
Measured From:
Finished Floor
Side of Unit
Top of Unit
Sidewall to Sidewall (Minimum)
Front to back wall (Maximum)

Advertisement

loading

Summary of Contents for Regency P33 SunriseTM P33S-LP4

  • Page 1: Clearance Requirements

    Regency P33 Sunrise Gas Fireplace Model P33S-NG4 Fuel Type Natural Gas Minimum Supply Pressure 5” W.C. (1.25 kPa) Manifold Pressure - High 3.5” W.C. (0.87 kPa) Manifold Pressure - Low 1.6” W.C. (0.39 kPa) Maximum Input 17,000 BTU/h Altitude 0-4500 ft. (0-1372m) (4.98 kW)
  • Page 2 Regency P33 Sunrise Gas Fireplace Venting Arrangements - Horizontal Terminations This lightly shaded area of the diagram shows allowable combinations of vertical runs with horizontal terminations, using one 45° and one 90° elbow (two 45º elbows equal one 90° elbow).

This manual is also suitable for:

P33 sunrisetm p33s-ng4P33s-ng4 sunriseP33s-lp4 sunrise