Step 6. WIRING - OPTIONAL FORCED AIR
BLOWER KIT
FBK-100, FBK-200 and FBK-250 Kits
(See Figure 52 for wiring)
An electrical receptacle is provided for the
installation of the FBK-100, FBK-200 and FBK-
250 forced air blower kits. Electrical power
must be connected to this receptacle in order
to operate these blowers. Install the blower
kits according to the installation instructions
provided with the kits.
CAUTION
Remove the carton support from
the control compartment before
operating the appliance.
Receptacle, Junction Box
and Cover Plate Installation
Outlet Receptacle
Junction Box
View Of Left
Bottom Corner Of Unit
Metal Junction Box
Cover Plate With Screw
Junction Box
knock-out (2
places each side)
Press snap
bushing into the
knock-out for
control switch
wires.
Figure 51
30
Pilot Burner
Assembly
Latching magnet
not shown
Optional Control Switch
Electronic Wiring Diagram (Honeywell) Showing Blower Wiring for Optional FBK-100, FBK-200 & FBK-250 Kits
Figure 52
Fireplace
Side
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Plug blower
Green
into this
receptacle
Blower
Ground
Tab Intact
Green
Neutral
Ground
Side of
Screw
Receptacle
View A
J-Box Wiring when
Relay Module C/W FBK-250 only. Plug blower
using unit mounted
into J-Box receptacle for FBK-100 or FBK-200
relay module.
application. See View A for J-Box wiring.
BK
W
G
Optional Blower
Junction Box
*OFF/ON Switch
(Integral with
Gas Valve)
Honeywell
Electronic
Gas
Valve
Igniter
Connector
BL
BL
BK
R
BK
BK
W
Schematic Representation Only
Installation and Operation Instructions
White
Black
Tab
Broken
Red
J-BOX WIRING FOR
Hot
WALL SWITCH
Side of
BLOWER CONTROL
Receptacle
* Leave the OFF/ON switch, which is
integral with the gas valve, in the ON
GROUND
position.
Transformer
**Optional Control Switches: Wall
Switch, Wall Thermostat or Remote
BL
Control Receiver.
24 V
120 VAC
Secondary
Notes:
Primary
1. If any of the original wire as supplied
must be replaced, use Type AWM 105°C
- 18 gage wire ONLY.
BK = BLACK BL = BLUE
2. 120 VAC, 60 Hz - Less than 3 Amps.
R = RED
W = WHITE
Caution: label all wires prior to
G = GREEN
disconnection when servicing controls.
Field Wired
Wiring errors can cause improper and
Factory
dangerous operation.
Wired
900299-00, 02/2019
G
o r
n u
- d
G
e r
n e
N
e
t u
a r
- l
W
h
e t i
120 VAC - Black
Junction Box
* Wall-mounted
ON/ OFF Blower
Switch or Variable
Speed Control Switch.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drt40stdenDrt40pfdenDrt40cldenDrt40crden

Table of Contents