Step 12. Hood Installation; Finishing Requirements - Superior Fireplaces DRT40 Series Installation And Operation Instructions Manual

Multi-view direct-vent gas fireplaces
Hide thumbs Also See for DRT40 Series:
Table of Contents

Advertisement

Innovative Hearth Products
DRT40 Multi-View Series Direct-Vent Gas Fireplace
Air Shutter
Adjusting
Rod
Increase Shutter
Opening In This
Direction
Decrease Shutter
Opening In This
Direction
Note - Burners are omitted in this view for clarity.
Note: The gas valve of your fireplace may be
different in appearance.
MAIN BURNER
FACTORY SHUTTER SETTING
Models
Natural Gas
inches (mm)
DRT40ST
DRT40PF
1/4"
DRT40CL
(6.35)
DRT40CR
Adjustment Rod Positions (when viewed from above)
Figure 62

Step 12. HOOD INSTALLATION

Refer to Figure 63. All of these appliances
must have hoods installed prior to operating.

FINISHING REQUIREMENTS

- Wall Details
Complete finished interior wall. To install the
appliance facing flush with the finished wall,
position framework to accommodate the thick-
ness of the finished wall (Figure 63)
See Page 7 for
Cold Climate Insulation and
Page 10 for Clearances
38
Orifice
Propane Gas
inches (mm)
Figure 63 - FINISHING REQUIREMENTS
5/8"
(15.88)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Combustible
Wall
Framing
Combustible
Finished Wall
Materials
Header
Top Spacers
Drywall
Bracket/Spacer
Top of Appliance
Top of
Door Frame
Hood must be
installed as shown.
Installation and Operation Instructions
This Area Must Remain
3" (77 mm)
Clear of Combustible
Materials
1" Min.
(26 mm)
900299-00, 02/2019